UEEEL0073 — Verify compliance and functionality of special LV electrical installations
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEEEL0073 must cover
61 assessable components: 4 elements (27 performance criteria), 11 performance evidence and 23 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to inspect and test an electrical installation
- 1.1Work health and safety (WHS)/occupational health and safety (OHS) measures for the site are identified, obtained and applied
- 1.2WHS/OHS risk control measures and procedures in preparation for the work are followed
- 1.3WHS/OHS hazards not previously identified are noted, risks assessed and risk control measures implemented
- 1.4Installation documentation and relevant industry standard are reviewed and applied
- 1.5Appropriate person/s is consulted to ensure the work is coordinated effectively with others
- 1.6Tools, equipment and testing devices needed to verify compliance are obtained in accordance with workplace procedures and checked for operation and safety
- 1.7Preparatory work is checked to ensure no damage has occurred in accordance with workplace procedures
2 Visually inspect the installation
- 2.1WHS/OHS risk control measures and procedures for carrying out the work are followed
- 2.2Need to inspect, test and measure live work is determined in accordance with WHS/OHS requirements and workplace procedures
- 2.3Circuits/machines/plant are checked and isolated in accordance with WHS/OHS requirements and workplace procedures
- 2.4Installed wiring is checked for suitability for the environments and protected from damage and overheating
- 2.5Cable conductor sizes acquired are inspected to meet current-carrying capacity requirements, voltage-drop and fault-loop impedance limitations in accordance with relevant industry standards
- 2.6Inspection protection methods and devices are validated to meet coordination requirements for overload and short circuit protection in accordance with relevant industry standards
- 2.7Switchgear and control gear are inspected, validated and appropriately rated to meet functional requirements in accordance with relevant industry standards
- 2.8Electrical equipment is checked for compliance with safety requirements in accordance with relevant industry standards
- 2.9Earthing system components are checked, located and conductors correctly sized in accordance with relevant industry standards
- 2.10Markings on switchboards are checked for accuracy and clarity in accordance with relevant industry standards
3 Conduct safety testing
- 3.1WHS/OHS risk control measures and procedures for carrying out the work are followed
- 3.2Need to test and measure live electrical work is conducted in accordance with WHS/OHS requirements and workplace procedures
- 3.3Circuits/machines/plant are checked and isolated in accordance with WHS/OHS requirements and workplace procedures
- 3.4Mandatory tests are conducted to verify earthing conductor resistance is sufficiently low; insulation resistance is sufficiently high; polarities are correct; circuit connections are correct; and tests are in accordance with relevant industry standards
- 3.5Inspection and testing are conducted to verify fault-loop impedance is sufficiently low and residual current device (RCD) operates as intended in accordance with job requirements and relevant industry standards
4 Report inspection and test findings
- 4.1WHS/OHS risk control work completion measures and workplace procedures are followed
- 4.2Worksite is cleaned and made safe in accordance with workplace procedures
- 4.3Non-compliance defects are identified and reported in accordance with workplace procedures
- 4.4Recommendations for rectifying defects are made in accordance with workplace procedures
- 4.5Mandatory documentation is completed in accordance with workplace procedures
Performance evidence
- selecting correct tools and testing equipment
- identifying visual non-compliance defects
- using effective methods for conducting mandatory and optional tests
- identifying non-compliance from test results
- identifying causes of non-compliance
- completing mandatory reporting
- dealing with unplanned events
- applying relevant work health and safety (WHS)/occupational health and safety (OHS requirements, including using risk control measures
- preparing, inspecting and testing an electrical installation
- reporting inspection and test findings
- reviewing relevant industry documentation
Knowledge evidence
- electrical installations, testing, compliance and functionality verification of special electrical installations, including:
- technical standards, regulations and codes for special electrical installations encompassing:
- additional requirements for special installations
- caravan parks
- construction and demolition sites
- marinas
- medical treatment areas
- moveable premises
- high voltage (HV) installation in consumer’s premises
- mandatory and optional testing and verification requirements applicable to special installations encompassing:
- testing techniques
- features of special installations that can be visually inspected
- caravan parks
- construction and demolition sites
- marinas
- medical treatment areas
- moveable premises
- HV installation in consumer’s premises
- relevant industry standards
- relevant job safety assessments or risk mitigation processes
- relevant WHS/OHS legislated requirements
- relevant workplace documentation
- relevant workplace policies and procedures
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEEEL0073
What does an assessment tool for UEEEL0073 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEEEL0073 needs to address all 61 unit components: 4 elements with 27 performance criteria, 11 performance evidence requirements, 23 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEEEL0073?
Auditori pulls the current release of UEEEL0073 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEEEL0073 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEEEL0073 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEEEL0073, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEEEL0001 — Apply compliance requirements to all aspects of electrical work
- UEEEL0002 — Apply currency of safe working practices and compliance verification of electrical installations
- UEEEL0003 — Arrange circuits, control and protection for electrical installations
- UEEEL0004 — Carry out basic repairs to electrical components and equipment
- UEEEL0005 — Develop and connect electrical control circuits
- UEEEL0006 — Develop detailed and complex drawings for electrical systems using CAD systems
- UEEEL0007 — Develop detailed electrical drawings
- UEEEL0008 — Evaluate and modify low voltage heating equipment and controls
- UEEEL0009 — Evaluate and modify low voltage lighting circuits, equipment and controls
- UEEEL0010 — Evaluate and modify low voltage socket outlets circuits
- UEEEL0011 — Evaluate performance of low voltage electrical apparatus
- UEEEL0012 — Install low voltage wiring, appliances, switchgear and associated accessories
Your UEEEL0073 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEEEL0073 free