UEEEL0009 — Evaluate and modify low voltage lighting circuits, equipment and controls
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEEEL0009 must cover
74 assessable components: 3 elements (16 performance criteria), 16 performance evidence and 42 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to work on lighting circuits
- 1.1Scope of work is obtained from relevant documentation, electrical drawings or relevant person/s
- 1.2WHS/OHS requirements and workplace procedures for a given work area are identified and applied
- 1.3Hazards are identified, risks are assessed and control measures are implemented
- 1.4Advice is sought from work supervisor to ensure the work is coordinated effectively with others
- 1.5Sources of materials required for work are determined in accordance with workplace procedures
- 1.6Tools, equipment and testing devices required to carry out work are obtained and checked for correct operation and safety
2 Evaluate and modify lighting circuits
- 2.1Equipment and circuits are checked and arrangement identified
- 2.2Circuits are checked and isolated in accordance with workplace procedures and regulatory requirements
- 2.3The need to test or measure live work is determined in accordance with WHS/OHS requirements and when necessary conducted in accordance with workplace procedures
- 2.4Fault/s and probable cause/s are identified from measured and calculated values as they apply to lighting equipment
- 2.5Required components are identified and replaced in accordance with manufacturer specifications and industry standards
- 2.6Unexpected situations are dealt with safely and with the approval of relevant person/s
3 Complete work and document activities
- 3.1WHS/OHS work completion risk control measures and workplace procedures are followed
- 3.2Worksite is cleaned and made safe in accordance with workplace procedures
- 3.3Justification for solutions used to modify circuits and equipment is documented
- 3.4Work completion is documented and an appropriate person/s notified in accordance with workplace procedures
Performance evidence
- # applying work health and safety (WHS)/occupational health and safety (OHS) workplace procedures, including:
- # identifying and assessing hazards and risks, and implementing control measures
- # checking circuits are isolated in accordance with workplace procedures and regulatory requirements
- # determining the operating parameters of existing lighting circuits and equipment
- # modifying existing lighting circuits and their controls to comply with specified operating parameters, including drawing and connecting lighting circuits that incorporate:
- one-way
- two-way
- # intermediate switching of light points using the loop at the light/switch methods of thermoplastic sheathed (TPS) wiring
- # developing lighting circuits and equipment to comply with a specified function and operating parameters
- # determining the cause of low illuminance level in existing lighting circuits and equipment
- determining conditions causing existing lighting circuits and equipment to be unsafe
- # connecting lighting equipment and controls
- # identifying faulty components in luminaires and auxiliary/control equipment from test results
- # testing luminaires and auxiliary/control equipment for serviceability
- ensuring all work complies with relevant Australian Standards and legislation
- completing work and documenting activities.
Knowledge evidence
- loop at the light method of wiring lighting circuits
- loop at the switch method of wiring lighting circuits
- installation methods of accessories and wiring for a lighting circuit incorporating one-way, two-way and intermediate switching of lighting points using the loop at the light/switch method of TPS wiring
- TPS cabling requirement for the loop at the light/switch circuit
- correct operation of the installed circuits including testing for compliance with industry standards
- emergency and evacuation lighting and lighting control, including:
- factors and requirements of emergency and evacuation lighting concerning illumination levels, luminaire positioning and operating period
- characteristics of maintained, non-maintained and sustained emergency lighting systems
- arrangement of batteries in point and central bank emergency lighting supply systems
- lighting control methods
- principles of lighting technology, including:
- basic electrical terminology
- colour theory
- lighting techniques
- local Supply Authority requirements for maintaining high power factor
- terminology, principles and standards relevant to lighting (energy efficiency as per National Construction Code (NCC))
- types of luminaires:
- different types of luminaires, their features and purpose
- operation of different types of luminaires
- expected lamp life, colour rendering and efficacy for typical types of different types of luminaires
- lighting circuits, equipment and controls used for the following applications:
- commercial
- industrial
- domestic
- lighting layout in terms of visual comfort and relevant Australian Standards
- Australian Standards and local requirements for lighting
- light-emitting diode (LED) lighting and its applications
- Neon, Argon and Xenon lighting and their applications
- comparison of incandescent, low intensity discharge, high intensity discharge, LED and other types of lighting
- fire protection – residential fire and smoke alarms, including:
- types of fire and smoke alarms
- regulations and standards requirements regarding residential fire and smoke alarms
- locations for residential fire and smoke alarms
- wiring methods for residential fire and smoke alarms
- operation of typical residential fire and smoke alarms
- identifying faults in luminaires and auxiliary/control equipment, including circuit and wiring diagrams of common lighting circuits, including:
- common fault symptoms and associated causes
- common faults in luminaires and auxiliary/control equipment
- techniques for repairing/replacing faulty lighting components
- input and output parameters of equipment incorporating electronic components for; controlling/switching lighting, auxiliary control equipment, energy measurement and control, rectifying and inverting electrical supplies
- hazards and safety requirements related to equipment incorporating electronic components used in electrical systems
- relevant manufacturer specifications.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEEEL0009
What does an assessment tool for UEEEL0009 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEEEL0009 needs to address all 74 unit components: 3 elements with 16 performance criteria, 16 performance evidence requirements, 42 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEEEL0009?
Auditori pulls the current release of UEEEL0009 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEEEL0009 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEEEL0009 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEEEL0009, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEEEL0001 — Apply compliance requirements to all aspects of electrical work
- UEEEL0002 — Apply currency of safe working practices and compliance verification of electrical installations
- UEEEL0003 — Arrange circuits, control and protection for electrical installations
- UEEEL0004 — Carry out basic repairs to electrical components and equipment
- UEEEL0005 — Develop and connect electrical control circuits
- UEEEL0006 — Develop detailed and complex drawings for electrical systems using CAD systems
- UEEEL0007 — Develop detailed electrical drawings
- UEEEL0008 — Evaluate and modify low voltage heating equipment and controls
- UEEEL0010 — Evaluate and modify low voltage socket outlets circuits
- UEEEL0011 — Evaluate performance of low voltage electrical apparatus
- UEEEL0012 — Install low voltage wiring, appliances, switchgear and associated accessories
- UEEEL0014 — Isolate, test and troubleshoot low voltage electrical circuits
Your UEEEL0009 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEEEL0009 free