UEEEL0044 — Diagnose and rectify faults in complex lift systems
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEEEL0044 must cover
99 assessable components: 3 elements (17 performance criteria), 24 performance evidence and 58 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to diagnose a lift system fault
- 1.1WHS/OHS workplace procedures for a given work area are identified and applied
- 1.2Scope of work to be undertaken is determined from maintenance procedures, fault/breakdown reports and/or discussions with appropriate person/s
- 1.3Advice is sought from the work supervisor to ensure the work is coordinated effectively with relevant others
- 1.4Tools, equipment and testing devices needed to carry out the work are obtained in accordance with workplace procedures and checked for correct operation and safety
2 Diagnose and rectify lift system faults
- 2.1WHS/OHS risk control measures and workplace procedures for carrying out work activities are followed
- 2.2Circuits/machines/plant are isolated in accordance with relevant industry standards and workplace procedures
- 2.3Safety hazards resulting from the fault and/or breakdown are documented and risk control measures implemented in consultation with appropriate person/s
- 2.4Diagnostics are applied to apparatus, equipment and systems to identify fault/s
- 2.5Suspected fault scenarios are tested as cause/s of system fault
- 2.6Cause of the fault is identified and appropriate person/s engaged to rectify the fault
- 2.7Faults in the lift components of the system are rectified in accordance with apparatus and system industry operational standards
- 2.8Apparatus, equipment and system/s are verified and tested to meet required industry standards
- 2.9Unplanned situations are responded to in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
- 2.10Diagnosis and rectification activities are carried out efficiently without waste of materials or damage to apparatus, the environment or services using sustainable energy practices
3 Complete work and report fault diagnosis and rectification activities
- 3.1Reusable, faulty or worn components are tagged and despatched for repair in accordance with workplace procedures
- 3.2Rectification of faults is documented in accordance with workplace procedures
- 3.3Rectification of faults is reported and appropriate person/s notified in accordance with workplace procedures
Performance evidence
- releasing passengers from a lift which has become immobilised
- diagnosing and repairing faults in lift circuits and associated components for at least three types of lift circuits/components, including:
- governors
- brakes
- safety gear
- safety devices
- lift machines
- door components
- controllers
- replacing and/or adjusting lift equipment in at least three types of lift equipment as described below:
- electro-hydraulic lift
- electric traction lift
- passenger lift
- goods lift
- dealing with unplanned events
- applying relevant industry standards
- applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including using risk control measures
- diagnosing and rectifying faults, including:
- inspecting, testing and measuring live electrical work
- obtaining and checking tools, equipment, resources and testing devices
- using diagnostic methods
- following workplace procedures and instructions
- reporting fault diagnosis and rectification activities, including:
- completing documentation.
Knowledge evidence
- lift components and systems - electrical/electronic, including:
- traction lifts encompassing:
- lift control circuits (relay logic only): floor selector circuitry
- machine room control (selector) and well control (transducer) circuitry - direction slowing and stopping, re-levelling, door operator, acceleration, button, indicator/lantern, lights and emergency lights, travelling cables, key switch circuits, fans, main supply and power circuits
- safety circuits encompassing:
- type, operation and actuation
- landing door locks, car door locks, emergency stop, pit switch, car trap-door switch, fire service, car top switch, tappet switch, governor switch, and safety gear switch, reverse phase relay, phrase failure relay and limit switches
- maintenance, replacement and adjustment encompassing:
- electrical and electronic lift components - travelling cables, tachometers, selectors, encoders and transducers
- safety devices: overloads, circuit breakers, limit switches, terminal stopping, door protection, governors and safety gear/switches
- electrical layout/drawings and special requirements encompassing:
- lift code and AS/NZS 3000 Electrical installations (known as the Australian/New Zealand Wiring Rules) requirements
- specific lift symbols
- conduits
- trailing cable
- troughing
- colour coding and labelling
- segregation low voltage (LV)/extra-low voltage (ELV)
- telephone and communication cabling
- regulatory requirements and door lock wiring
- safety drive adjustment encompassing:
- emergency stop button
- speed governor
- reverse phase protection
- broken chain/step switch
- broken main drive switch
- drive access switch
- start pressure switch and landing guards/barriers
- lift components – electronic encompassing:
- encoders
- transducers
- electronic boards
- selectors
- rectifiers
- capacitors
- resistors
- processor board
- input/output (I/O) board
- drives - types, construction and operation encompassing:
- traction
- gearless types:
- speed/load characteristics, efficiency, application, brakes and electric prime mover (motor types and control)
- geared types:
- speed/load characteristics, efficiency, application, brakes and electric prime mover (motor types and control)
- other types of lifts (drum, rack and pinion, chain and screw)
- fault finding encompassing:
- visual inspection
- performance checks and application of fault-finding principles
- relevant diagnostic methods
- relevant fault scenarios
- relevant industry standards
- relevant job safety assessments or risk mitigation processes
- relevant manufacturer specifications and operating instructions for tools and equipment
- relevant rectification activities and procedures
- relevant tools, equipment and testing devices
- relevant WHS/OHS legislated requirements
- relevant workplace documentation, including fault reports, test results, authorisations, permits, parts/components, despatch and store records
- relevant workplace policies, procedures and instructions
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEEEL0044
What does an assessment tool for UEEEL0044 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEEEL0044 needs to address all 99 unit components: 3 elements with 17 performance criteria, 24 performance evidence requirements, 58 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEEEL0044?
Auditori pulls the current release of UEEEL0044 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEEEL0044 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEEEL0044 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEEEL0044, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEEEL0001 — Apply compliance requirements to all aspects of electrical work
- UEEEL0002 — Apply currency of safe working practices and compliance verification of electrical installations
- UEEEL0003 — Arrange circuits, control and protection for electrical installations
- UEEEL0004 — Carry out basic repairs to electrical components and equipment
- UEEEL0005 — Develop and connect electrical control circuits
- UEEEL0006 — Develop detailed and complex drawings for electrical systems using CAD systems
- UEEEL0007 — Develop detailed electrical drawings
- UEEEL0008 — Evaluate and modify low voltage heating equipment and controls
- UEEEL0009 — Evaluate and modify low voltage lighting circuits, equipment and controls
- UEEEL0010 — Evaluate and modify low voltage socket outlets circuits
- UEEEL0011 — Evaluate performance of low voltage electrical apparatus
- UEEEL0012 — Install low voltage wiring, appliances, switchgear and associated accessories
Your UEEEL0044 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEEEL0044 free