UETDRSO012 — Coordinate and manage distribution and sub-transmission network access and activities
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UETDRSO012 must cover
76 assessable components: 3 elements (19 performance criteria), 35 performance evidence and 22 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to coordinate and manage distribution and sub-transmission network access and activities
- 1.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be done are reviewed and determined
- 1.2Purpose of the coordination is established after data is analysed and expected outcomes of the work are confirmed with appropriate personnel
- 1.3Work plans are obtained and confirmed in accordance with workplace requirements
- 1.4Systems modelling is used to evaluate and determine best outcomes for work plans in accordance with workplace requirements
- 1.5Work roles and tasks are determined according to requirements and individual competencies
- 1.6Work is prioritised and sequenced for completion in accordance with work plan and workplace requirements
- 1.7Liaison and communication issues with authorised personnel, authorities and clients are resolved to facilitate work, as required
- 1.8Hazards are identified, risks assessed, and control measures identified and applied
- 1.9Work permits are determined in accordance with workplace requirements
2 Coordinate and manage distribution and sub-transmission network access and activities
- 2.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be performed are applied and monitored
- 2.2Work plans are evaluated and monitored for best outcomes in accordance with workplace requirements
- 2.3Coordination and management decisions are made in accordance with best outcomes, safety control measures, and workplace requirements
- 2.4Work teams are coordinated according to best outcomes, individual competencies and workplace requirements
- 2.5Work permits are received and signed in accordance with workplace requirements
- 2.6Incidents or unplanned events are responded to in accordance with workplace requirements
3 Complete work and documentation
- 3.1Completed work is checked for compliance against the work plan and workplace requirements
- 3.2Incidents or unplanned events are reported in accordance with workplace requirements
- 3.3Work permits are signed off in accordance with workplace requirements
- 3.4Work records, reports and documentation are completed, and appropriate personnel notified in accordance with workplace requirements
Performance evidence
- applying relevant legislation, regulations, standards, codes of practice and organisational workplace requirements including:
- work health and safety (WHS)/occupational health and safety (OHS) requirements
- identifying hazards, assessing risks, and identifying, applying and monitoring control measures
- dealing with an unplanned event on at least one (1) occasion
- obtaining and signing on and off relevant work permits in accordance with workplace requirements
- completing relevant work records, reports and documentation
- evaluating and monitoring work plans for best outcomes in accordance with workplace requirements
- making coordination decisions in accordance with best outcomes, safety control measures, and workplace requirements
- coordinating and managing at least one (1) work team according to best outcomes, individual competencies and workplace requirements
- coordinating and managing one (1) work plan for access to each of the following:
- high voltage (HV) transformer
- HV switchgear
- HV lines
- HV bus
- coordinating and managing one (1) work plan, which considers at least two (2) of the following:
- commissioning of HV plant
- planned interruption to HV customer
- installation of a mobile generator
- consideration of paralleling feeders
- HV switching impact on low voltage (LV) customers
- HV capacitors
- HV regulators
- managing all of the following for each of the work plans:
- load
- voltage
- system reliability
- critical customers
- completing all of the following:
- checking switching instructions
- calculating plant loading
- monitoring switching progress
- monitoring the status of access permits and authorities
- ensuring network plant operates within specifications
- applying and administrating supervisory control and data acquisition (SCADA)
- meeting paralleling conditions for interconnected networks.
Knowledge evidence
- relevant legislation, regulations, standards, codes of practice and organisational workplace requirements, including WHS/OHS requirements
- hazard, risk assessment and risk control requirements, including possible hazards
- events constituting an unplanned event or incident
- procedures for responding to an unplanned event or incident
- workplace records, reports and documentation
- application, purpose, and types of permits, and access authority procedures
- coordination and management of work teams for best outcomes, individual competencies and workplace requirements
- interconnected HV electrical networks, including fundamentals of HV single wire earth return (SWER) system
- principles of harmonics
- principles of resonant networks
- fault levels and settings
- load calculation
- operating agreements
- types, characteristics and capabilities of electrical apparatus
- types, characteristics and capabilities of specialised tools and testing equipment
- manuals, system diagrams, plans and drawings
- HV switching principles, including:
- HV switching operator responsibilities
- sources of possible back-feed
- restrictions on electrical apparatus
- HV isolation procedures
- HV earthing procedures.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UETDRSO012
What does an assessment tool for UETDRSO012 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UETDRSO012 needs to address all 76 unit components: 3 elements with 19 performance criteria, 35 performance evidence requirements, 22 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UETDRSO012?
Auditori pulls the current release of UETDRSO012 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UETDRSO012 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UETDRSO012 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UETDRSO012, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UETDRSB001 — Perform substation switching operations to a given schedule
- UETDRSB002 — Commission and maintain discrete control and protection systems
- UETDRSB003 — Commission and maintain distribution field devices
- UETDRSB004 — Conduct surveys using thermovision techniques
- UETDRSB005 — Diagnose and resolve faults in a substation environment
- UETDRSB006 — Inspect substations
- UETDRSB007 — Install and maintain substation direct current systems
- UETDRSB008 — Install high current d.c. equipment and switchgear
- UETDRSB009 — Install high voltage plant and equipment
- UETDRSB010 — Maintain capacitor bank equipment
- UETDRSB011 — Maintain high current d.c. equipment and switchgear
- UETDRSB012 — Maintain high voltage circuit breakers
Your UETDRSO012 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UETDRSO012 free