UEERL0005 — Locate and rectify faults in low voltage (LV) electrical equipment using set procedures
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEERL0005 must cover
41 assessable components: 3 elements (18 performance criteria), 16 performance evidence and 7 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to identify faults
- 1.1Work is planned to ensure WHS/OHS policies and workplace procedures are applied
- 1.2Tools, electrical equipment and testing devices required for work are obtained in accordance with workplace procedures and checked for correct operation and safety
- 1.3Relevant person/s is consulted to ensure the work is coordinated with others
- 1.4Electrical characteristics of electrical equipment and electrical supply are determined and recorded in accordance with workplace procedures
- 1.5Electrical equipment and associated circuits are identified for isolation purposes in accordance with workplace procedures
2 Locate faults in the electrical equipment
- 2.1Electrical equipment and associated circuits are isolated in accordance with workplace procedures
- 2.2WHS/OHS workplace policies and procedures are followed
- 2.3Visual inspection and checks of the electrical equipment and components are carried out to detect any abnormality, damage or fault in accordance with workplace procedures
- 2.4Wiring diagrams are checked and possible fault causes identified based on the wiring diagrams
- 2.5Faults are confirmed and components to be replaced or adjusted are determined and details recorded in accordance with workplace procedures
- 2.6Electrical equipment is dismantled and/or removed, as required, and components stored to protect them against loss or damage in accordance with workplace procedures
- 2.7Quality checks of work are undertaken in accordance with workplace procedures
3 Rectify faults
- 3.1Materials and resources required to complete work are obtained in accordance with workplace procedures and job requirements
- 3.2Adjustments are made to electrical equipment for operation and parameters in accordance with manufacturers requirements, workplace procedures and relevant industry standards
- 3.3Faults are rectified in accordance with workplace procedures
- 3.4Approval for contingencies is obtained from appropriate person/s before implementation in accordance with workplace procedures
- 3.5Tests on the electrical equipment are performed in accordance with industry procedures to ensure safe return to service and operation of equipment
- 3.6Report/s, documentation and compliance certifications are completed in accordance with workplace, industry and regulatory requirements
Performance evidence
- applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including: selecting and using and appropriate range of personal protective equipment (PPE) hazard identification using risk control measures using safe working practices when carrying out electrical disconnect/reconnect work working safely with low voltage (LV) electrical installations dealing with unplanned events
- using routine fault-finding techniques, workplace procedures and problem-solving techniques to locate and rectify faults in LV electrical equipment
- following safe work method statements (SWMS) and procedures
- using wiring diagrams to assist in identifying fault locations
- identifying, inspecting, testing and isolation of electrical equipment
- preparing to replace, implementing repairs and reconnecting electrical equipment
- applying safe procedures to discharge a capacitor
- returning to service and testing for polarity, continuity and insulation resistance
- using safe working practices when carrying out fault finding
- identifying common types of electrical faults (open circuit, short circuit, partial open circuit and partial short circuit)
- interpreting ratings from nameplates for comparison with any replacement
- visual checking techniques on a range of single and multi-phase equipment
- using test instrumentation, safely conduct procedures to identify faults in a range of single and multi-phase equipment
- rectifying all identified faults and ensuring appropriate consultation/approval before implementing contingencies
- checking repaired equipment for safe and correct operation
- producing reports and documents for the identification and rectification of faults in electrical LV equipment in accordance with workplace procedures and regulatory and compliance documentation.
Knowledge evidence
- safe fault finding, including: identification of common types of electrical faults (open circuit, short circuit, partial open circuit and partial short circuit) in single and multi-phase equipment test equipment to locate common faults techniques for using wiring diagrams to identify possible fault locations
- types of single and multi-phase equipment, including: identifying basic principles of operation of typical equipment visual inspection and checking techniques on a range of single/multi-phase equipment interpretation of ratings from nameplates for comparison with any replacement principles of operation of control equipment and protection devices associated with a range of single/multi-phase equipment
- problem-solving techniques, including: symptoms of common faults common faults that occur in single and multi-phase equipment and the indicators of such faults techniques to ensure the electrical isolation and the maintenance of electrical isolation of single/multi-phase equipment when conducting fault finding regulatory requirements/obligations regarding any live testing that may be unavoidable fault-finding procedures rectification of identified faults ensuring appropriate consultation/approval before implementing contingencies
- documentation and reporting- including: reporting and recording systems relevant workplace documentation, including quality, policies and procedures status reports and documents related to locating and identifying isolation mechanisms for a wide range of circuits and associated loads reports, documents and procedures related to safely locating and rectifying faults in electrical LV equipment relevant job safety assessments or risk mitigation processes include safe working methods statements
- relevant industry standards, including AS/NZS 4836 Safe working on or near low-voltage electrical installations and equipment
- relevant manufacturer specifications
- relevant WHS/OHS legislated requirements.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEERL0005
What does an assessment tool for UEERL0005 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEERL0005 needs to address all 41 unit components: 3 elements with 18 performance criteria, 16 performance evidence requirements, 7 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEERL0005?
Auditori pulls the current release of UEERL0005 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEERL0005 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEERL0005 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEERL0005, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEERL0001 — Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply
- UEERL0002 — Attach cords, cables and plugs to electrical equipment for connection to 1000 V a.c. or 1500 V d.c.
- UEERL0003 — Conduct in-service safety testing of electrical cord connected equipment and cord assemblies
- UEERL0004 — Disconnect - reconnect electrical equipment connected to low voltage (LV) installation wiring
- UEERL0006 — Attach HV flexible cables and plugs
- UEERL0007 — Disconnect-reconnect 3.3 kV electric propulsion components of self-propelled earth moving vehicles
- UEERL0008 — Disconnect-reconnect explosion-protected appliances and control devices connected to LV installation