What an assessment for UEERL0002 must cover
68 assessable components: 4 elements (19 performance criteria), 11 performance evidence and 38 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Plan electrical equipment connection
- 1.1Work is planned, sequenced and prepared in accordance with WHS/OHS requirements and workplace procedures
- 1.2Condition and ratings of cords, cables and plugs is in accordance with workplace procedures and work instruction from relevant person/s
- 1.3Flexible cords, cables and plugs are selected in accordance with relevant industry standards and workplace procedures for condition and rating
- 1.4Materials necessary to complete work are obtained in accordance with workplace procedures and checked against work instructions
- 1.5Tools, equipment and testing devices needed to carry out work are obtained in accordance with workplace procedures and checked for correct operation and safety
- 1.6Flexible cords, cables and plugs are prepared without damage to insulation and conductors and in accordance with relevant industry standards
2 Attach flexible cords, cables and plugs
- 2.1WHS/OHS policies and workplace procedures are followed
- 2.2Single insulated metal framed equipment is earthed in accordance with relevant industry standards and workplace procedures
- 2.3Double insulated equipment is inspected and maintained in accordance with relevant industry standards and workplace procedures
- 2.4Conductors are connected to terminals ensuring required polarity is in accordance with relevant industry standards
3 Inspect and test equipment for operation and safety
- 3.1Electrical installation and operation of the cord/cable/s and plug/s connected to equipment are inspected and tested in accordance with relevant industry standards, work instructions and workplace procedures
- 3.2Quality checks of work are undertaken in accordance with workplace procedures
4 Locate and repair faults in attached flexible cords, cables and plugs
- 4.1Electrical equipment and attached flexible cords, cables and plugs are checked and isolated in accordance with workplace procedures
- 4.2WHS/OHS policies and workplace procedures are followed
- 4.3Visual inspection and checks of the attached flexible cords, cables and plugs are conducted in accordance with workplace procedures to detect any abnormal, damage or fault
- 4.4Faults in attached flexible cords, cables and plugs are confirmed and determined, components to be replaced are identified and details recorded in accordance with workplace procedures
- 4.5Faults in attached flexible cords, cables and plugs are repaired in accordance with workplace procedures
- 4.6Unplanned events are referred to relevant person/s for direction in accordance with workplace procedures
- 4.7Status report/s is completed in accordance with workplace procedures
Performance evidence
- applying relevant industry standards
- applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including using risk control measures
- applying to quality, workplace procedures and instructions
- attaching cords, cables and plugs to electrical equipment for connection to 1,000 volts (V) alternating current (a.c.) or 1,500 volts (V) direct current (d.c.) supply
- attaching, replacing and repairing flexible cords, cables and plugs to equipment for operation, safely up to 1,000 V a.c. to 1,500 V d.c.
- dealing with unplanned events in accordance with problem-solving techniques and workplace procedures
- finding and repairing fault/s in attached flexible cords, cables and plugs
- inspecting and testing flexible cords, cables, plugs and equipment for operation and safety up to 1,000 V a.c. to 1,500 V d.c.
- planning and preparing to attach flexible cords, cables and plugs up to 1,000 V a.c. to 1,500 V d.c.
- providing status reports
- replacing and repairing flexible cords, cables and plugs up to 1,000 V a.c. to 1,500 V d.c.
Knowledge evidence
- safety, including:
- WHS/OHS and electrical safety requirements
- requirements of AS/NZS 4836 Safe working practices on low voltage installations
- selection of flexible cords, cables and plugs to suit given applications, including:
- multi-phase systems
- structure of plug pin configuration
- applications of commonly used flexible cords, cables and plugs for connection to 1,000 V a.c. or 1,500 V d.c. supply
- determining the current rating of a range of commonly used flexible cords, cables and plugs for connection to 1,000 V a.c. or 1,500 V d.c. supply
- determining the number of cores/pins required for given situations
- multi-phase colour code and the conventional code used in the most common cords and cables
- selecting flexible cords and cables for given multi-phase loads to 1,000 V and service duty
- selecting multi-phase plugs to 1,000 V for a given load and ingress protection (IP) rating
- selecting the correct plug and socket combinations for a range of applications, including use in damp areas
- flexible cords, cables and plugs connected to multi-phase equipment, including:
- design features of plugs and sockets which protect the conductor terminations from undue force when disconnecting a cord - tortuous path
- cord preparation - not to mark/damage the inner core when stripping the sheath for termination, double the end of the conductor to be terminated
- preparation of the surfaces at an earthing connection before and after completion of the termination, including terminations exposed to corrosion, and those for which no specific earthing terminal is provided
- prepare flexible cords, cables for connection
- single insulated metal framed equipment is earthed in accordance with requirements or the integrity of double insulated equipment is maintained
- fitting a range of various multiphase flexible cords, cables, plugs, and sockets with attention to tortuous path requirements, colour code, polarity and correct termination of conductors with the sheath well into the body, and the cord grip anchored
- determine that a flexible cord, cable and plug is safe and is connected correctly, including:
- importance of conducting both visual and electrical tests to ensure leads are safe and appropriate for connection to supply in regard to physical condition, sufficiently high insulation resistance, continuity, arrangements for protection against indirect contact are undamaged and in place, appropriate IP rating, and arrangements for protection against dangers of mechanical movement as relevant are undamaged and in place
- check polarity of plug, and for any abnormal or obvious damage or fault
- minimum acceptable value of insulation resistance between actives, neutral and earth
- insulation resistance and continuity tests prior to, and after, connecting cords, cables and plugs to appliances
- fault finding attached multi-phase flexible cords, cables and plugs, and multi-phase cord extension leads
- producing documentation and reports, including:
- nature and content of, and the need to produce, status reports and documents
- producing status reports and documents
- problem-solving techniques
- producing documentation and reports
- relevant industry standards
- relevant job safety assessments or risk mitigation processes
- relevant manufacturer specifications and operating instruction for tools, equipment and testing devices
- relevant WHS/OHS legislated requirements, including relevant inspections and tests
- relevant workplace policies, procedures and instructions
- relevant workplace quality procedures
- selection of flexible cords, cables and plugs to suit given applications.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEERL0002
What does an assessment tool for UEERL0002 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEERL0002 needs to address all 68 unit components: 4 elements with 19 performance criteria, 11 performance evidence requirements, 38 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEERL0002?
Auditori pulls the current release of UEERL0002 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEERL0002 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEERL0002 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEERL0002, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEERL0001 — Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply
- UEERL0003 — Conduct in-service safety testing of electrical cord connected equipment and cord assemblies
- UEERL0004 — Disconnect - reconnect electrical equipment connected to low voltage (LV) installation wiring
- UEERL0005 — Locate and rectify faults in low voltage (LV) electrical equipment using set procedures
- UEERL0006 — Attach HV flexible cables and plugs