UEERL0001 — Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEERL0001 must cover
94 assessable components: 4 elements (20 performance criteria), 18 performance evidence and 56 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Plan electrical equipment connection
- 1.1Work is planned, sequenced and prepared in accordance with WHS/OHS requirements and workplace procedures
- 1.2Condition and ratings of cord and plugs are in accordance with workplace procedures and work instruction from appropriate person/s
- 1.3Flexible cords and plugs are selected in accordance with relevant industry standards and workplace procedures for condition and rating
- 1.4Materials necessary to complete work are obtained and checked in accordance with workplace procedures and work instructions
- 1.5Tools, equipment and testing devices needed to carry out work are obtained in accordance with workplace procedures and checked for correct operation and safety
- 1.6Flexible cord and plugs are prepared without damage to insulation and conductors and in accordance with relevant industry standards
2 Attach flexible cord and plugs
- 2.1WHS/OHS workplace policies and procedures are followed
- 2.2Single insulated metal framed equipment is earthed in accordance with relevant industry standards and workplace procedures
- 2.3Double insulated equipment is inspected and maintained in accordance with relevant industry standards and workplace procedures
- 2.4Conductors are connected to terminals ensuring required polarity is in accordance with relevant industry standards
3 Inspect and test equipment for operation and safety
- 3.1Electrical installation and operation of cord and plug/s connected to electrical equipment are inspected and tested in accordance with relevant industry standards, work instructions and workplace procedures
- 3.2Quality checks of work are undertaken in accordance with workplace procedures
4 Locate and repair fault in flexible cord and plug/s
- 4.1Electrical equipment and attached flexible cord and plug/s are isolated in accordance with WHS/OHS requirements and workplace procedures
- 4.2WHS/OHS workplace policies and procedures are followed
- 4.3Quality checks of the attached flexible cord and plug/s are undertaken in accordance with workplace procedures to detect any abnormal, damage or fault
- 4.4Faults in attached flexible cord and plug/s are determined and details of components to be replaced are recorded in accordance with workplace procedures
- 4.5Faults in attached flexible cord and plug/s are repaired, as required, in accordance with workplace procedures
- 4.6Repairs are inspected and tested for compliance with industry standards
- 4.7Unplanned events are referred to supervisor for direction in accordance with workplace procedures
- 4.8Status report/s is completed and supervisor notified in accordance with workplace procedures
Performance evidence
- applying relevant industry standards
- applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including using risk control measures
- applying quality to workplace procedures and instructions
- attaching flexible cord/s and plug/s and without damage
- inspecting flexible cords and plugs for damage, faults or abnormalities
- dealing with unplanned events in accordance with problem-solving techniques and workplace procedures
- determining the current rating of a range of commonly used flexible cords
- drawing of a basic electrical circuit using correct symbols
- testing flexible cords, plugs and connected equipment for operation and safety up to 230 volts (V) alternating current (a.c.), including polarity and continuity testing
- finding and repairing faults in attached flexible cords and plugs in accordance with established procedures
- preparing to attach flexible cord and plug supplies up to 230 V a.c. supply
- providing status report/s
- using testing equipment
- selecting appropriate flexible cords for a range of single phase appliances relating to application, load and service duty
- identifying correct plug and socket polarities for the range of commonly used 230 V plug socket combinations
- selecting the correct plug and socket combinations for a range of applications, including use in damp areas
- fitting a range of various plugs and sockets with attention to requirements, colour code, polarity and correct termination of conductors with the sheath well into the body, and the cord grip anchored
- terminating cords to several appliances utilising the appropriate cord type and rating.
Knowledge evidence
- electrical safety requirements, including the requirements of AS/NZS 4836 Safe working on low-voltage electrical installations
- basic electrical circuits, including:
- simple electric circuit (supply, control device and load)
- industry standard symbols, units of measurement and the abbreviation for electromotive force, potential difference, current and resistance
- using multiples and sub-multiples for voltage, current and resistance values
- a.c and direct current (d.c.) supplies
- single phase electrical loads
- electrical circuit protection devices
- relationships in an electrical circuit, including:
- relationship between voltage, current and resistance (Ohm’s Law)
- changes in circuit parameters for altered values of voltage, current and resistance
- electrical power in relationship to d.c. or resistive a.c. circuits
- test equipment - resistance measurement, including:
- types of electrical test equipment used for resistance measurement (analogue and digital multimeters, insulation resistance testers and continuity testers)
- selection of appropriate electrical test instrument for continuity and insulation resistance measurement
- using analogue and digital multimeters for resistance measurement (ensuring zero setting, correct scale selection, avoidance of parallax error and estimation of between division readings for analogue multimeters)
- continuity tests and using a continuity tester to check the polarity of a three-core extension cord
- insulation resistance tests and minimum values for insulation resistance for low voltage (LV) equipment
- reasons for insulation resistance testing is conducted at higher than supply voltage to relevant industry standards
- using insulation resistance handheld tester
- care and storage of electrical instruments
- regulatory requirements relating to the maintenance and testing of test instrumentation for resistance measurement
- selection of flexible cords and plugs to suit given applications, including:
- types, structures and applications of common cores, including:
- parallel two core unsheathed (‘figure 8’)
- cords, light duty sheathed
- ordinary duty sheathed
- heavy duty sheathed
- textile braided
- service duty
- purpose of colour coding and the recommended single phase colour code
- conventional code used in the most common alternative colours
- factors affecting the choice of plugs and sockets, including ingress protection (IP) rating
- connecting flexible cords and plugs to appliances, including:
- design features of plugs and sockets which protect the conductor terminations from undue force when disconnecting a cord - tortuous path
- cord preparation - not to mark/damage the inner core when stripping the sheath for termination, double the end of the conductor to be terminated
- purpose of earthing
- structure of double insulated appliances, symbol, reasons they should not be earthed, and maintenance of the integrity of the double insulation
- preparation of the surfaces at an earthing connection before and after completion of the termination, including terminations exposed to corrosion, and those for which no specific earthing terminal is provided
- techniques for fitting plugs and sockets
- techniques for terminating cords and conductors including consequences of poor electrical terminations
- testing, including:
- importance of conducting both visual and electrical tests to ensure leads are safe and appropriate for connection to supply in regard to physical condition
- checking the polarity of plug, and for any abnormal or obvious damage or fault
- minimum acceptable value of insulation resistance between active neutral and earth
- conducting insulation resistance and continuity tests prior to, and after, connecting cords and plugs to appliances
- visually checking that the cord/plug assembly has a suitable IP rating for the operating environment
- visual checks to ensure that arrangements for protection against dangers of mechanical movement as relevant are undamaged and in place
- techniques for fault finding attached cords and plugs, and cord extension leads
- producing documentation and reports, including:
- nature and content of, and the need to produce, status reports and documents
- relevant WHS/OHS legislated requirements including inspection and testing of electrical equipment
- relevant industry standards
- relevant manufacturer specifications and operating instruction for tools, equipment and testing devices
- relevant safe job safety assessments or risk mitigation processes
- relevant workplace policies, procedures and instructions, including relevant workplace quality procedures.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEERL0001
What does an assessment tool for UEERL0001 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEERL0001 needs to address all 94 unit components: 4 elements with 20 performance criteria, 18 performance evidence requirements, 56 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEERL0001?
Auditori pulls the current release of UEERL0001 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEERL0001 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEERL0001 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEERL0001, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEERL0002 — Attach cords, cables and plugs to electrical equipment for connection to 1000 V a.c. or 1500 V d.c.
- UEERL0003 — Conduct in-service safety testing of electrical cord connected equipment and cord assemblies
- UEERL0004 — Disconnect - reconnect electrical equipment connected to low voltage (LV) installation wiring
- UEERL0005 — Locate and rectify faults in low voltage (LV) electrical equipment using set procedures
- UEERL0006 — Attach HV flexible cables and plugs
- UEERL0007 — Disconnect-reconnect 3.3 kV electric propulsion components of self-propelled earth moving vehicles
- UEERL0008 — Disconnect-reconnect explosion-protected appliances and control devices connected to LV installation
Your UEERL0001 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEERL0001 free