UETDRIS015 — Install low voltage mobile generator
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UETDRIS015 must cover
29 assessable components: 3 elements (19 performance criteria), 7 performance evidence and 3 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to install LV mobile generator
- 1.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be performed are referred to and confirmed
- 1.2Work plan is obtained and confirmed in accordance with workplace requirements
- 1.3Materials required for work are determined and obtained in accordance with work plan and workplace requirements
- 1.4Plant, tools, equipment and personal protective equipment (PPE) required for work are determined, obtained and confirmed in working order
- 1.5Hazards are identified, risks assessed and control measures identified and applied
- 1.6Work is prioritised and sequenced for completion in accordance with work plan and workplace requirements
- 1.7Worksite is prepared in accordance with the work plan and workplace requirements
- 1.8Traffic management plan is confirmed as being in place in accordance with workplace requirements
2 Carry out the installation of LV mobile generator
- 2.1Legislation, regulations, standards, codes of practice and organisational workplace requirements for the work to be performed are applied and monitored
- 2.2Lifting, climbing, working at heights and the use of plant, tools, equipment and PPE are carried out in accordance with workplace requirements
- 2.3Hazard control measures are monitored in accordance with workplace requirements
- 2.4LV mobile generator is installed in accordance with the work plan and workplace requirements
- 2.5LV mobile generator is synchronised to LV network in accordance with the work plan and workplace requirements
- 2.6LV mobile generator is monitored in accordance with the work plan and workplace requirements
3 Complete work and documentation
- 3.1Completed work is checked for compliance against the work plan and workplace requirements
- 3.2Worksite is rehabilitated, cleaned and made safe in accordance with workplace requirements
- 3.3Plant, tools and equipment are cleaned, checked and returned to storage in accordance with workplace requirements
- 3.4Surplus materials are returned to storage or disposed of in accordance with workplace requirements
- 3.5Work records, reports and documentation are completed in accordance with workplace requirements
Performance evidence
- applying relevant legislation, regulations, standards, codes of practice and organisational workplace requirements, including: work health and safety (WHS)/occupational health and safety (OHS); identifying hazards, assessing risks, identifying, applying and monitoring control measures; obtaining, inspecting and using relevant personal protective equipment (PPE)
- operating a generator
- connecting a generator
- disconnecting a generator
- synchronising of generator onto the low voltage (LV) network without interruption to supply
- synchronising of generator off the LV network without interruption to supply
- completing relevant work records, reports and documentation
Knowledge evidence
- relevant legislation, regulations, standards, codes of practice and organisational workplace requirements, including: WHS/OHS; hazard, risk assessment and risk control requirements, including potential hazards; types and application of PPE; safe use of plant, tools and equipment; events constituting an unplanned event or incident; safety precautions specific to installing mobile generators
- techniques in the connecting, operating and disconnecting of generators, including: synchronising of generator control systems onto and off the network without interruption to supply; estimation of LV load; assessing the appropriateness of the generator; multiple generators
- connections to the network, including: overhead; indoor substations; customer installations; kiosk substations
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UETDRIS015
What does an assessment tool for UETDRIS015 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UETDRIS015 needs to address all 29 unit components: 3 elements with 19 performance criteria, 7 performance evidence requirements, 3 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UETDRIS015?
Auditori pulls the current release of UETDRIS015 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UETDRIS015 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UETDRIS015 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UETDRIS015, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UETDRIS007 — Install and maintain distribution overhead conductors and cables
- UETDRIS008 — Install and maintain electrical apparatus
- UETDRIS010 — Install and maintain low voltage overhead services
- UETDRIS011 — Install and maintain low voltage underground services
- UETDRIS012 — Install and maintain poles, structures and hardware
- UETDRIS013 — Install and maintain public lighting systems
- UETDRIS014 — Install and replace energy meters and associated equipment
- UETDRIS017 — Perform high voltage field switching operation to a given schedule
- UETDRIS018 — Perform low voltage field switching operation to a given schedule
- UETDRIS020 — Contribute to coordinated high voltage live work
- UETDRIS021 — Coordinate and direct switching programs
- UETDRIS022 — Coordinate permit procedures
Your UETDRIS015 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UETDRIS015 free