UEERE0059Design energy management controls for electrical installations in buildings

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for UEERE0059 must cover

70 assessable components: 2 elements (12 performance criteria), 3 performance evidence and 55 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Identify energy management techniques for electrical installations in buildings

  • 1.1Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures are identified and applied
  • 1.2Scope of the energy management electrical design is determined from specifications of building and its services, plant and machinery and in consultation with relevant person/s
  • 1.3People or organisations involved in the design and installation are identified and roles clarified
  • 1.4Industry regulations, legal obligations and job requirements are identified and applied to work in accordance with workplace procedures

2 Design energy management controls for electrical installations

  • 2.1Energy management controls’ performance standards and compliance methods are applied to the design development
  • 2.2Inspection, tests and measurements are carried out in accordance with WHS/OHS requirements and workplace procedures
  • 2.3Energy use of building services, plant and machinery is obtained and applied to the energy management design control process
  • 2.4Energy evaluation tests are set up in accordance with inspection and test methods and workplace procedures
  • 2.5Strategies to reduce electrical system energy use without compromising occupancy standards are developed in accordance with energy management techniques and evaluation test results
  • 2.6Safety, functional and budgetary considerations are incorporated in design
  • 2.7Results of energy management design controls, recommended electrical installation strategies and their criterion for energy reduction are documented in accordance with workplace procedures
  • 2.8Plans, wiring diagrams and specifications are completed and forwarded to relevant person/s

Performance evidence

  • applying relevant workplace procedures and practices, work health and safety (WHS)/occupational health and safety (OHS) requirements, including using risk control measures
  • designing energy management controls for electrical installations in accordance with design brief, site, client, safety and functional requirements and budget limitations
  • documenting and presenting final design

Knowledge evidence

  • functions of a building management system (BMS) including:
  • protocol and priority of systems
  • different types and suppliers of building management systems
  • autonomous functions
  • input/output (I/O)
  • general I/O
  • installation management items
  • energy management
  • risk management
  • information processing
  • objectives
  • building running costs
  • smoke control as per relevant industry standards
  • BMS hardware including:
  • system architecture
  • communication devices
  • substations
  • personal computers
  • interfaces with other systems
  • I/O functions including:
  • digital I/O
  • digital output with status feedback
  • analogue I/O
  • sensors
  • alarms
  • equipment data protocols
  • energy management including:
  • night cycle
  • optimum stop/start
  • time and event programs
  • night purge
  • outside air percentage control
  • enthalpy control
  • power demand control
  • duty cycle
  • presence detection
  • lighting control
  • schemes to promote to incorporate renewables and energy storage optimisation
  • financial stability
  • maximise benefit/investment
  • information processing functions including:
  • computer systems
  • central system management
  • programs
  • system configuration and security
  • operator - machine interface
  • data points
  • risk and maintenance management including:
  • system files
  • fire and intruder control
  • access control
  • relevant manufacturer specifications
  • technical expertise required to support design and where/when they are required
  • relevant WHS/OHS requirements
  • relevant workplace documentation, policies and procedures

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UEERE0059

What does an assessment tool for UEERE0059 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEERE0059 needs to address all 70 unit components: 2 elements with 12 performance criteria, 3 performance evidence requirements, 55 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UEERE0059?

Auditori pulls the current release of UEERE0059 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEERE0059 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UEERE0059 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEERE0059, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your UEERE0059 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate UEERE0059 free