UEERE0018 — Maintain and repair remote area power generation facilities
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEERE0018 must cover
58 assessable components: 3 elements (18 performance criteria), 15 performance evidence and 25 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to maintain and repair remote area power generation facilities
- 1.1Work health and safety (WHS)/occupational health and safety (OHS) requirements for a remote area power generation facility are identified and applied in accordance with workplace routines and procedures
- 1.2Risks are identified, assessed and control measures applied in accordance with workplace procedures prior to commencing work
- 1.3Risks/hazards are identified, assessed, reported to relevant person/s and control measures implemented
- 1.4Nature and location of remote area power station facility is obtained from documentation or from relevant person/s to determine the scope of work
- 1.5Advice on coordinating work with others and the local community is obtained from relevant person/s and applied
- 1.6Sources of materials required for work are identified and accessed in accordance with workplace routines and procedures
- 1.7Tools, equipment and testing devices required for work are obtained and checked for correct operation and safety
2 Maintain and repair remote area power generation facilities
- 2.1Workplace risk control measures and procedures are applied
- 2.2Circuits/machines/plant are isolated in accordance with WHS/OHS requirements and workplace procedures
- 2.2Inspection repairs, replacements and/or adjustments are completed on items listed in the maintenance schedule and in accordance with workplace procedures
- 2.3Fuel, coolant, oil and other fluid spills are cleaned and area made safe in accordance with workplace procedures
- 2.4Batteries are serviced and/or replaced as specified in the maintenance schedule and in accordance with workplace procedures
- 2.5Consumables are removed and disposed of in accordance with environmentally safe procedures
- 2.6Non-routine events are referred to relevant person/s for directions in accordance with workplace procedures
- 2.7Quality checks are conducted in accordance with instructions and workplace procedures
3 Report maintenance and repair of remote area power generation facilities
- 3.1Workplace risk control measures and procedures are applied
- 3.2Maintenance issues beyond the scope of work are referred to relevant person/s in accordance with workplace procedures
- 3.3Work completed is reported to relevant person/s in accordance with maintenance reporting and workplace procedures
Performance evidence
- understanding the location and nature of the work required
- applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures and practices, including the use of risk control measures
- determining scope of work from documentation and/or relevant person/s
- identifying and accessing materials, tools, equipment and testing devices
- coordinating work with relevant person/s
- checking isolation of circuits/machines/systems
- correctly inspecting, repairing, replacing and adjusting items listed in the maintenance schedule
- maintaining and repairing remote area power generation facilities
- servicing batteries and battery packs in a community power station
- cleaning fluid spills appropriately
- removing and disposing of consumable following environmentally safe procedures
- conducting quality checks
- dealing with unplanned events
- applying environmentally safe work practices
- completing relevant documentation/reporting.
Knowledge evidence
- remote area essential services power plant, including:
- minor service and maintenance procedures of diesel-powered generation equipment in accordance with a prepared schedule encompassing:
- types and grades of inspections, repairs, replacement and/or adjustments under a maintenance schedule:
- replacement items/materials, including engine oil, oil filters, fuel filters, engine coolant system filters, air cleaners and fan belts
- inspection and repair items, including leakages from fuel system, coolant system and lubricating oil system
- cleaning of fluid spills
- environmentally safe procedures for removal and disposal of consumables
- servicing batteries and battery packs in a community power station in accordance with the prepared maintenance schedule encompassing:
- hazards associated with batteries
- types of batteries and their application in a community power station (starting battery set and switchboard (nicad) batteries)
- battery maintenance techniques
- schedule regular servicing and maintenance encompassing:
- engine oil and filter changes
- fuel filters
- coolant filters
- water trap devices
- drive belt (condition/adjustment)
- valve adjustments (if applicable)
- major and minor mechanical servicing by outside agents
- air cleaner (both dry paper and oil bath types)
- relevant manufacturer specifications
- relevant safe work method statements (SWMS)/job safety assessments or risk mitigation processes
- relevant WHS/OHS legislated requirements
- relevant workplace documentation
- relevant workplace policies and procedures.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEERE0018
What does an assessment tool for UEERE0018 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEERE0018 needs to address all 58 unit components: 3 elements with 18 performance criteria, 15 performance evidence requirements, 25 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEERE0018?
Auditori pulls the current release of UEERE0018 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEERE0018 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEERE0018 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEERE0018, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEERE0001 — Apply environmentally and sustainable procedures in the energy sector
- UEERE0006 — Conduct periodic maintenance of remote area power supply battery banks
- UEERE0007 — Conduct periodic maintenance of remote area power supply generator sets
- UEERE0008 — Conduct periodic maintenance of remote area power supply photovoltaic arrays
- UEERE0009 — Conduct periodic maintenance of remote area power supply wind generators
- UEERE0013 — Develop strategies to address environmental and sustainability issues in the energy sector
- UEERE0015 — Implement and monitor energy sector environmental and sustainable policies and procedures
- UEERE0049 — Apply safe work practices in the rooftop solar industry
- UEERE0050 — Identify and isolate multiple supply systems
- UEERE0051 — Apply electrical principles to renewable energy design
- UEERE0052 — Assess energy loads and uses for energy efficiency in commercial facilities
- UEERE0053 — Assess energy loads and uses for energy efficiency in industrial properties and enterprises
Your UEERE0018 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEERE0018 free