UEERA0094 — Verify functionality and compliance of refrigeration and air conditioning installations
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEERA0094 must cover
48 assessable components: 4 elements (24 performance criteria), 11 performance evidence and 13 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to verify refrigeration and air conditioning installation
- 1.1WHS/OHS hazards, risk control methods, relevant standards, codes and legislation are obtained and applied
- 1.2Safety hazards which have not previously been identified are noted on job safety assessment and established risk control measures implemented
- 1.3Appropriate person/s is consulted to ensure the verification work is coordinated effectively with others involved on the worksite
- 1.4Location of refrigeration and air conditioning system components are determined from specifications and diagrams
- 1.5Refrigeration and air conditioning inspection and tests are appropriately sequenced in accordance with job schedule
- 1.6Materials needed for the tests and verification are obtained in accordance with workplace procedures and checked against job requirements
- 1.7Tools, equipment and testing devices needed to verify compliance are obtained in accordance with workplace procedures and checked for correct operation and safety
2 Visually inspect the refrigeration and air conditioning installation
- 2.1Circuits/machines/plant are checked and isolated in accordance with WHS/OHS requirements and workplace procedures
- 2.2Pipe work is checked for appropriate type and size
- 2.3Pipe work accessories and components are validated as being suitably located, securely fixed and suitably protected from damage or corrosion
- 2.4Refrigeration and air conditioning system components and accessories are validated as being appropriately rated in accordance with manufacturer and design specifications
- 2.5Evidence that equipment complies with safety and functional requirements is cited in accordance with workplace procedures
- 2.6Unexpected situations are responded to in a manner that minimises risk to personnel and equipment, discussed with appropriate person/s and documented in accordance with workplace procedures
- 2.7Visual inspection is carried out efficiently without waste of materials, damage to or contamination of apparatus and the surrounding environment or services using sustainable energy practices
3 Conduct refrigeration and air conditioning compliance tests
- 3.1Testing or measuring on live electrical work and operating system is conducted in accordance with WHS/OHS requirements and workplace safety procedures
- 3.2Circuits/machines/plant are checked and isolated in accordance with WHS/OHS requirements and workplace procedures
- 3.3Electrical tests are conducted to verify that the electrical circuit within the refrigeration and air conditioning installation is safe and functions as intended
- 3.4Refrigeration and air conditioning tests are conducted to verify that the refrigeration equipment and pipe work within the refrigeration installation is safe and functions as intended
- 3.5Unexpected situations are responded in a manner that minimises risk to personnel and equipment, discussed with appropriate person/s and documented in accordance with workplace procedures
- 3.6Refrigeration/air conditioning testing is carried out efficiently without waste of materials or damage to apparatus, the surrounding environment or services using sustainable energy practices
4 Report refrigeration and air conditioning inspection and verification findings
- 4.1Worksite and equipment are cleaned and made safe in accordance with established procedures
- 4.2Non-compliance defects are identified and reported in accordance with workplace procedures
- 4.3Recommendations for rectifying defects are made in accordance with workplace procedures
- 4.4Work completion is documented and appropriate person/s notified in accordance with workplace procedures
Performance evidence
- applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures and practices, including: using risk control measures, using personal protective equipment (PPE), acting within regulatory limits, implementing legislation, industry standards, codes of practice and regulations, applying sustainable energy principles and practices, completing reporting in accordance with workplace procedures
- conducting all refrigeration tests safely and correctly, including: pressure testing, leak testing, evacuation testing, controls tests, refrigerant charge, operating pressures and system operation
- conducting electrical tests safely and correctly, including: isolation, testing of insulation resistance of equipment, resistance of the internal circuits of equipment, polarity of supply and equipment, continuity of earthing, and correct electrical connections and load current
- dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
- identifying non-compliant defects from test results
- identifying visual defects
- planning refrigeration and air conditioning installation compliance inspections and testing
- reading and interpreting drawings and requirements related to the installation
- recommending appropriate corrective actions
- selecting, obtaining and checking relevant equipment, materials, tools and testing devices required to carry out the work
- using manufacturer specifications and manuals
Knowledge evidence
- refrigeration and air conditioning installation functionality tests and verification methods
- refrigeration and air conditioning installation tests and verification methods, including visual inspections, mandatory tests and verification requirements
- refrigeration testing requirements and procedures, including: controls, leak test, operating pressures and temperatures, pressure test, refrigerant charge, vacuum electrical testing requirements and procedures, including: isolation and tagging off, continuity of earthing: correct electrical connections, isolation testing: insulation resistance of equipment, load current, polarity of supply and equipment, resistance of the internal circuits of equipment, insulation resistance of the equipment
- relevant environmental and sustainable principles and practices, including: environment protection, sustainable energy, sustainable resources
- relevant equipment, materials, tools and testing devices, including: air pressure and flow measurement and testing devices, electrical measuring and testing devices, including multimeters, megohm meters (insulation resistance tester) and ammeters, pressure testing and leak testing equipment and tools, including oxygen-free dry nitrogen cylinder and regulator, refrigerant pressure and temperature measuring and testing devices, refrigerant PPE, refrigeration and electrical hand and power tools, vacuum pump and electronic vacuum measuring device
- relevant industry standards, codes of practice and regulations
- relevant installation specifications and drawings
- relevant job safety assessments or risk mitigation processes, including electrical safe working practices
- relevant refrigeration and air conditioning manufacturer specifications and instructions
- relevant WHS/OHS legislated requirements
- relevant workplace documentation
- relevant workplace policies and procedures
- verifying compliance and functionality of refrigeration and air conditioning installations
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEERA0094
What does an assessment tool for UEERA0094 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEERA0094 needs to address all 48 unit components: 4 elements with 24 performance criteria, 11 performance evidence requirements, 13 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEERA0094?
Auditori pulls the current release of UEERA0094 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEERA0094 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEERA0094 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEERA0094, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEERA0001 — Analyse the operation of HVAC air and hydronic systems
- UEERA0002 — Analyse the psychrometric performance of HVAC/R systems
- UEERA0003 — Analyse the thermodynamic performance of HVAC/R systems
- UEERA0004 — Analyse vibration and noise in refrigeration and air conditioning systems
- UEERA0005 — Apply safety awareness and legal requirements for ammonia refrigerant
- UEERA0006 — Apply safety awareness and legal requirements for carbon dioxide refrigerant
- UEERA0007 — Apply safety awareness and legal requirements for flammable refrigerants
- UEERA0008 — Audit HVAC/R control systems for compliance with regulations and standards
- UEERA0009 — Audit energy use for commercial HVAC/R systems
- UEERA0010 — Commission complex heating, ventilation and air conditioning (HVAC) systems
- UEERA0011 — Commission complex refrigeration systems and equipment
- UEERA0012 — Commission complex refrigeration/air conditioning control systems
Your UEERA0094 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEERA0094 free