What an assessment for UEERA0003 must cover

136 assessable components: 3 elements (15 performance criteria), 10 performance evidence and 111 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Prepare to analyse thermodynamic performance of HVAC/R system

  • 1.1Work health and safety (WHS)/occupational health and safety (OHS) processes and workplace procedures for a given work area are identified and applied
  • 1.2WHS/OHS risk control measures and workplace procedures are followed in preparation for HVAC/R work
  • 1.3Extent of the thermodynamic issues are determined from performance specifications and situation reports and in consultation with relevant person/s
  • 1.4HVAC/R activities are planned to meet scheduled timelines in consultation with others involved in the work
  • 1.5Strategies are formed to ensure HVAC/R analysis and solution implementation is carried out efficiently in accordance with workplace procedures

2 Analyse thermodynamic performance of HVAC/R system

  • 2.1WHS/OHS risk control measures and workplace procedures for carrying out HVAC/R work are followed
  • 2.2Thermodynamic principles are applied to analytical solutions to HVAC/R system
  • 2.3Parameters, specifications and performance requirements in relation to HVAC/R system are obtained in accordance with workplace procedures
  • 2.4Analysis of HVAC/R thermodynamic parameters is carried out to provide effective solution/s
  • 2.5Unplanned events are dealt with safely and effectively in accordance with regulatory requirements and workplace procedures in a manner that minimises risk to personnel and equipment
  • 2.6Quality of work is monitored against performance agreement and/or workplace procedures or industry standards

3 Document and report results of the HVAC/R thermodynamic performance analysis and actions taken

  • 3.1Solutions to HVAC/R thermodynamic issues are evaluated to determine their effectiveness and modified, as required
  • 3.2HVAC/R analysis is documented and includes details of findings, calculations and assumptions
  • 3.3HVAC/R analysis is reported to appropriate person/s to determine appropriate action to be taken based on findings
  • 3.4Justification for findings and any actions to be undertaken in relation to the HVAC/R equipment is documented for inclusion in work/project or development records in accordance with industry standards and workplace procedures

Performance evidence

  • understanding the thermodynamic performance issues
  • forming effective strategies for analysing refrigeration and air conditioning systems performance
  • obtaining thermodynamic performance parameters, specifications and performance requirements appropriate to each situation
  • evaluating the results of the analysis
  • documenting analysis details of all findings, calculations and assumptions
  • documenting justification of actions to be implemented in accordance with professional standards
  • dealing with unplanned events
  • applying problem-solving techniques
  • applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, workplace procedures and practices, including using risk control measures
  • applying sustainable energy principles and practices

Knowledge evidence

  • refrigeration systems, safe working practices and relevant standards, codes and regulations, including:
  • major components, type and functions:
  • evaporators
  • compressors
  • expansion devices
  • ancillary components
  • refrigerants
  • system operation and performance:
  • thermodynamic properties of refrigerants
  • pressure enthalpy charts
  • refrigerant cycle
  • refrigerant cycle represented on pH charts
  • introduction to refrigerating effect, heat of compression, heat rejected on high side, co-efficient of performance, liquid sub-cooling suction superheating
  • effects on performance of changing operating pressures, liquid sub-cooling, suction superheating
  • application of refrigeration:
  • introduction to industrial refrigeration, specific system component types and refrigerants
  • scope of commercial refrigeration, specific system component types and refrigerants
  • refrigerated enclosures and cabinets:
  • merchandising and display cabinets:
  • deep freeze meat
  • dairy
  • fruit and vegetable
  • multi-deck display
  • single deck
  • well type
  • island cases
  • glass door
  • reach door
  • reach in merchandisers
  • defrosting methods
  • cold rooms and freezer rooms
  • types and construction
  • insulation
  • vapour barrier
  • frost heave
  • interior fittings
  • location of equipment
  • defrosting methods
  • cold tracking
  • trace heating
  • storage conditions
  • temperature
  • relative humidity
  • air velocity
  • air patterns
  • load limits
  • air conditioning systems
  • introduction to air conditioning systems, safe working practices and relevant standards, codes and regulations, including:
  • WHS/OHS requirements:
  • Building Code of Australia (BCA) requirements
  • AS 1668 The use of ventilation and air conditioning in buildings parts 1 and 2
  • AS/NZS 3666 Air-handling and water systems of buildings
  • noise and vibration
  • air quality
  • sick building syndrome
  • operating requirements:
  • ventilation
  • air distribution
  • terminal velocity
  • temperature
  • relative humidity
  • air quality
  • noise
  • basic psychrometrics
  • operating modes:
  • ventilation
  • evaporative cooling
  • ventilation and cooling
  • ventilation and heating
  • dehumidification
  • dehumidification and reheat
  • humidification
  • operating terminology/characteristics:
  • throw and drop
  • primary and secondary air
  • coanda effect
  • heating, ventilation and air conditioning (HVAC) system components and functions:
  • fans
  • ducting
  • registers
  • dampers
  • filters
  • cooling coils
  • heating coils
  • induction units
  • fan coil units
  • terminal units
  • humidifiers, pumps and sprayers
  • hydronic systems and components
  • applications and construction of air conditioning systems:
  • applications
  • residential, commercial, low and high rise, industrial ventilation and air conditioning
  • packaged plant
  • split systems (wall and floor console, ceiling fan coil), wall facia, roof top and reverse cycle option central station plant
  • all air systems, constant volume variable temperature, constant temperature variable volume, and air/water systems
  • all water system, multi-zoning, thermal storage systems
  • basic air conditioning system diagrams
  • duct layout
  • hydronic layout
  • unit/conditioner drawings
  • HVAC control systems:
  • basic principles
  • terminology
  • symbols and diagrams
  • basic applications
  • problem-solving techniques
  • relevant HVAC/R manufacturer specifications
  • relevant job safety assessments or risk mitigation processes
  • relevant workplace documentation
  • relevant workplace policies and procedures
  • typical thermodynamic performance issues

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UEERA0003

What does an assessment tool for UEERA0003 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEERA0003 needs to address all 136 unit components: 3 elements with 15 performance criteria, 10 performance evidence requirements, 111 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UEERA0003?

Auditori pulls the current release of UEERA0003 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEERA0003 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UEERA0003 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEERA0003, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your UEERA0003 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate UEERA0003 free