What an assessment for UEERA0079 must cover

35 assessable components: 3 elements (13 performance criteria), 8 performance evidence and 14 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Prepare to transfer/decant refrigerants and lubricants

  • 1.1WHS/OHS hazards, risk control methods, relevant industry standards, codes of practice and legislation are obtained and applied in accordance with workplace procedures
  • 1.2Work details are determined from documentation and/or supervisor to establish scope of work to be completed in accordance with workplace procedures
  • 1.3Work tasks are sequenced in accordance with job schedule and workplace procedures
  • 1.4Supervisor is consulted to ensure work is coordinated with others in accordance with workplace procedures
  • 1.5Tools, equipment and testing devices to complete the work are obtained and checked for operational safety in accordance with workplace procedures

2 Transfer/decant refrigerants and lubricants

  • 2.1Checks are carried out to ensure cylinders and/or containers employed in the refrigerant transfer and/or decanting process are fit for purpose and free of contaminants in accordance with workplace procedures and industry standards
  • 2.2Calculations are performed to determine the safe filling capacity of the transfer/storage cylinder/container in accordance with workplace procedures and industry standards
  • 2.3Refrigerants and lubricants are transferred/decanted safely using appropriate equipment, and the cylinders/containers are labelled in accordance with relevant codes of practice and industry standards
  • 2.4Refrigerants and lubricants are transferred/decanted without waste of materials and damage to apparatus, the surrounding environment and services using relevant sustainable energy practices in accordance with workplace procedures and industry standards
  • 2.5Leaks are located and rectified using appropriate testing methods in accordance with relevant codes of practice and industry standards

3 Complete and report on transfer/decanting of refrigerants and lubricants

  • 3.1WHS/OHS work completion risk control measures are applied in accordance with workplace procedures
  • 3.2Worksite and equipment are cleaned and made safe in accordance with workplace procedures
  • 3.3Completion of work is documented in an auditable logbook and supervisor notified in accordance with workplace procedures

Performance evidence

  • applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including using risk control measures
  • determining the safe fill capacity of a refrigerant cylinder
  • safely handle refrigerants in accordance with standards, codes and regulatory requirements
  • documenting work, including refrigerant usage and removal
  • implementing relevant legislation, industry standards, codes of practice and regulations
  • testing for refrigerant leaks
  • transferring and decanting refrigerant
  • transferring lubricant

Knowledge evidence

  • compressor lubricant transferring equipment, procedures and requirements
  • compressor lubricant types, applications, properties and safe handling
  • decanting methods, including pressure differential, including pumping and temperature differential
  • environmental impact of climate change, including global warming potential (GWP)
  • environmental impact of ozone depletion, including ozone depletion potential (ODP)
  • leak detection methods, equipment, procedures and requirements
  • properties of an ideal refrigerant
  • refrigerant cylinder requirements and safe handling, including recovery cylinders
  • refrigerant properties, including classes, types and applications, boiling point, glide, composition, including components and safe handling, including flammability, toxicity and high pressure
  • relevant legislation, industry standards, codes of practice and regulations
  • relevant risk mitigation processes while handling refrigerants and lubricants, including potential hazards, risk control methods and safe working practices
  • safe fill ratios and relevant calculations
  • system contamination, prevention and removal, including types of contaminants and their effects on the operation of a system
  • terms, including primary, secondary, expendable, pure, azeotropic, zeotropic, blends, bubble point, dew point and critical point

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UEERA0079

What does an assessment tool for UEERA0079 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEERA0079 needs to address all 35 unit components: 3 elements with 13 performance criteria, 8 performance evidence requirements, 14 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UEERA0079?

Auditori pulls the current release of UEERA0079 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEERA0079 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UEERA0079 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEERA0079, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your UEERA0079 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate UEERA0079 free