UEERA0068 — Repair and service self-contained carbon dioxide refrigeration and heat pump systems
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEERA0068 must cover
79 assessable components: 3 elements (21 performance criteria), 12 performance evidence and 46 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to service self-contained CO² refrigeration and heat pump system
- 1.1WHS/OHS hazards, risk control methods, relevant standards, codes and legislation are obtained and applied
- 1.2Safety hazards not previously identified are reported, risk assessed and advice on risk control measures sought from work supervisor
- 1.3Nature of work is obtained from documentation or from work supervisor to determine the scope of work to be undertaken
- 1.4Advice is sought from work supervisor to ensure the work is coordinated effectively with others
- 1.5Sources of materials required for the refrigeration work are accessed in accordance with workplace and procedures
- 1.6Tools, equipment and testing devices needed to carry out refrigeration work are obtained and checked for correct operation and safety
2 Service and repair self-contained CO² refrigeration and heat pump system
- 2.1Measuring system operating parameters are conducted in accordance with WHS/OHS requirements and workplace safety procedures
- 2.2Refrigeration inspection and checks are carried out to ensure the system or component parts are isolated in accordance with WHS/OHS requirements and workplace procedures
- 2.3Refrigerant is removed from system safely in accordance with regulatory requirements, industry standards and practices
- 2.4Precautions are taken to prevent damage to components while pressure testing the refrigeration and heat pump system
- 2.5Pressure testing is conducted at a pressure compatible with CO² and in accordance with industry standards and practices
- 2.6Refrigerant leaks are located and rectified using testing methods appropriate to the system and in accordance with industry standards and practices
- 2.7Refrigeration and heat pump system is evacuated to the required level and cleaned of all moisture and other contaminants in accordance with industry standards and practices
- 2.8Refrigeration and heat pump system is charged safely with refrigerant grade CO² and compatible lubricants in accordance with industry standards and practices
- 2.9Actual and specified range of operating conditions are determined from measured and calculated values as they apply to CO² vapour compression systems in accordance with workplace procedures and industry standards
- 2.10Unplanned situations are dealt with safely and in accordance with workplace procedures and approval of authorised person/s in a manner that minimises risk to personnel and equipment
- 2.11Operating conditions are determined without damage to apparatus, circuits, the surrounding environment or services using sustainable energy practices
3 Complete and report servicing and repair of self-contained CO² refrigeration and heat pump system work activities
- 3.1Worksite is cleaned and made safe in accordance with workplace procedures
- 3.2Contaminated refrigerant and lubricant are dealt with in accordance with legislative/regulatory and industry standard requirements
- 3.3Operation conditions are documented and include identification of any parameter that is not within the specified range for the system
- 3.4Work supervisor is notified of the completion of work in accordance with workplace procedures
Performance evidence
- applying relevant legislation, industry standards and practices
- applying relevant work health and safety (WHS)/occupational health and safety (WHS/OHS) requirements and workplace procedures and practices, including using risk control measures
- applying sustainable energy principles and practices
- dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
- discharging/charging refrigerant/lubricants and pressure testing the system without damage to components
- documenting operating conditions correctly
- identifying the conditions of the carbon dioxide (CO²) refrigerant at various locations in the vapour compression system in a trans-critical and sub-critical state
- locating and rectifying leaks
- pressure testing, evacuating, charging/discharging refrigerant/lubricants and determining the operating conditions of CO² vapour compression systems
- recording measurements
- selecting and using appropriate measuring devices correctly
- using calculation methods accurately
Knowledge evidence
- CO² refrigeration compressors and lubricants, including:
- types, construction and their applications
- types of compatible compressor oil (Polyolester (POE) and Polyaphalefin (PAO))
- safe handling of lubricants for CO² applications using safety data sheets (SDS)/material safety data sheets (MSDS)
- cylinder regulators
- moisture problems with CO² systems
- refrigerant CO² cylinders and regulators
- refrigerant conditions
- refrigeration principles
- relevant industry standards, codes and practices
- relevant job safety assessments or risk mitigation processes, including hazards associated with CO²
- relevant manufacturer specifications
- relevant WHS/OHS legislated requirements
- relevant workplace documentation, including service manuals and service documentation
- relevant workplace policies and procedures
- self-contained systems employing CO² refrigerant at trans-critical condition, including:
- basic operation
- domestic refrigerators and freezers
- heat pumps
- water heaters
- refrigerated cabinets
- systems and major components
- typical applications
- service gauges
- service procedures
- CO² refrigerant, including:
- benefits of using CO² as a refrigerant
- thermophysical properties
- servicing tools, equipment and safe working procedures, including:
- cylinder regulators
- moisture problems with CO² systems
- refrigerant CO² cylinders and regulators
- refrigerant conditions
- service gauges
- service procedures
- system standing pressure as a result of power loss
- system components, construction and operation, including:
- capillary tubes and accurators
- CO² evaporator design features
- CO² sub-cooler design features
- electronic expansion valves
- liquid-suction heat exchangers
- pressure relief devices
- refrigerant flow controls
- system standing pressure as a result of power loss.
- trans-critical CO² refrigeration and heat pump systems.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEERA0068
What does an assessment tool for UEERA0068 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEERA0068 needs to address all 79 unit components: 3 elements with 21 performance criteria, 12 performance evidence requirements, 46 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEERA0068?
Auditori pulls the current release of UEERA0068 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEERA0068 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEERA0068 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEERA0068, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEERA0001 — Analyse the operation of HVAC air and hydronic systems
- UEERA0002 — Analyse the psychrometric performance of HVAC/R systems
- UEERA0003 — Analyse the thermodynamic performance of HVAC/R systems
- UEERA0004 — Analyse vibration and noise in refrigeration and air conditioning systems
- UEERA0005 — Apply safety awareness and legal requirements for ammonia refrigerant
- UEERA0006 — Apply safety awareness and legal requirements for carbon dioxide refrigerant
- UEERA0007 — Apply safety awareness and legal requirements for flammable refrigerants
- UEERA0008 — Audit HVAC/R control systems for compliance with regulations and standards
- UEERA0009 — Audit energy use for commercial HVAC/R systems
- UEERA0010 — Commission complex heating, ventilation and air conditioning (HVAC) systems
- UEERA0011 — Commission complex refrigeration systems and equipment
- UEERA0012 — Commission complex refrigeration/air conditioning control systems