UEERA0066 — Repair and service carbon dioxide refrigeration systems
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEERA0066 must cover
41 assessable components: 3 elements (21 performance criteria), 17 performance evidence and 3 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to service CO² refrigeration system
- 1.1WHS/OHS hazards, risk control methods, relevant standards, codes and legislation are obtained and applied
- 1.2Safety hazards not previously identified are assessed, reported and advice on risk control measures sought from work supervisor
- 1.3Nature of refrigeration work is obtained from documentation or from work supervisor to determine the scope of refrigeration work to be undertaken
- 1.4Advice is sought from work supervisor to ensure refrigeration work is coordinated effectively with others
- 1.5Sources of materials required for the work are accessed in accordance with workplace and procedures
- 1.6Tools, equipment and testing devices needed to carry out refrigeration work are obtained and checked for correct operation and safety
2 Service and repair CO² refrigeration system
- 2.1Measuring refrigeration system operating parameters is conducted in accordance with WHS/OHS requirements and workplace safety procedures
- 2.2Inspection and checks are carried out to ensure the refrigeration system or component parts are isolated in accordance with WHS/OHS requirements, industry standards and practices
- 2.3Refrigerant is removed from refrigeration system safely in accordance with WHS/OHS requirements, industry standards and practices
- 2.4Precautions are taken to prevent damage to components while pressure testing refrigeration system
- 2.5Pressure testing is conducted at a pressure compatible with CO² and in accordance with WHS/OHS requirements, industry standards and practices
- 2.6Leaks are located and rectified using testing methods appropriate to the refrigeration system and in accordance with industry standards and practices
- 2.7Refrigeration system is evacuated to the required level and cleaned of moisture and other contaminants in accordance with industry standards and practices
- 2.8Refrigeration system is charged safely with refrigerant grade CO² and compatible lubricants in accordance with industry standards and practices
- 2.9Actual and specified range of operating conditions are determined from measured and calculated values as they apply to sub-critical CO² vapour compression and liquid recirculation/cascade systems in accordance with workplace procedures
- 2.10Unplanned situations are responded to and discussed with appropriate person/s and documented in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
- 2.11Refrigeration operating conditions are determined without damage to apparatus, circuits, the surrounding environment or services using sustainable energy practices
3 Complete work and report on servicing CO² refrigeration system
- 3.1Worksite is cleaned and made safe in accordance with workplace procedures
- 3.2Contaminated refrigerant and lubricant are dealt with in accordance with legislative/regulatory requirements
- 3.3Operation conditions are documented and include identification of any parameters that are not within the specified range for the refrigeration system
- 3.4Work supervisor is notified of the completion of work in accordance with established procedures
Performance evidence
- applying relevant legislative, industry standards and practices
- applying relevant work health and safety (WHS)/occupational health and safety (WHS/OHS) requirements and workplace procedures and practices, including using risk control measures
- applying sustainable energy principles and practices
- completing work and reporting on servicing and repairing sub-critical carbon dioxide (CO²) refrigeration systems
- conducting work observing the relevant legislation, regulations, polices and workplace procedures
- dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
- decontaminating and evacuating the system
- discharging/charging refrigerant/lubricants and pressure testing the system without damage to components
- documenting operating conditions correctly
- identifying the conditions of the CO² refrigerant at various locations in the vapour compression and volatile secondary (liquid recirculation) system
- locating and rectifying leaks
- preparing to service and repair CO² refrigeration systems
- pressure testing, charging/discharging refrigerant/lubricants and determining the operating conditions of CO² vapour compression and volatile secondary (liquid recirculation) system
- recording measurements
- selecting and using appropriate measuring devices correctly
- servicing and repairing CO² refrigeration systems
- using calculation methods accurately
Knowledge evidence
- CO² refrigeration systems, including: basic CO² refrigeration system, basic liquid recirculation /cascade system employing CO² refrigerant at sub-critical condition, benefits of using CO² as a refrigerant, thermophysical properties
- operating conditions of CO² refrigeration systems, including: applicable standards and codes, CO² refrigeration compressors and lubricants, system components, construction and operation
- servicing and repair techniques for CO² refrigeration systems, including: moisture problems with CO² systems, refrigerant conditions, refrigerant cylinders and regulators, service gauges, service procedures, system standing pressure as a result of power loss
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEERA0066
What does an assessment tool for UEERA0066 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEERA0066 needs to address all 41 unit components: 3 elements with 21 performance criteria, 17 performance evidence requirements, 3 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEERA0066?
Auditori pulls the current release of UEERA0066 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEERA0066 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEERA0066 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEERA0066, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEERA0001 — Analyse the operation of HVAC air and hydronic systems
- UEERA0002 — Analyse the psychrometric performance of HVAC/R systems
- UEERA0003 — Analyse the thermodynamic performance of HVAC/R systems
- UEERA0004 — Analyse vibration and noise in refrigeration and air conditioning systems
- UEERA0005 — Apply safety awareness and legal requirements for ammonia refrigerant
- UEERA0006 — Apply safety awareness and legal requirements for carbon dioxide refrigerant
- UEERA0007 — Apply safety awareness and legal requirements for flammable refrigerants
- UEERA0008 — Audit HVAC/R control systems for compliance with regulations and standards
- UEERA0009 — Audit energy use for commercial HVAC/R systems
- UEERA0010 — Commission complex heating, ventilation and air conditioning (HVAC) systems
- UEERA0011 — Commission complex refrigeration systems and equipment
- UEERA0012 — Commission complex refrigeration/air conditioning control systems