What an assessment for UEEHA0038 must cover
35 assessable components: 3 elements (8 performance criteria), 6 performance evidence and 21 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare for inspection
- 1.1Safe work methods for undertaking visual and close inspections are obtained and interpreted
- 1.2Knowledge of the purpose, scope and limitations of visual and close inspections is applied to preparation for the work
- 1.3Type and location of each item of equipment subject to inspection are determined from the inspection program for the site
2 Carry out verification of compliance
- 2.1Safe work methods for undertaking visual and close inspections in hazardous areas, including isolation of equipment, are applied
- 2.2Knowledge of defects impairing the integrity of the type of protection that are identifiable by visual and close inspection is applied
- 2.3Equipment is visually and closely inspected and defects impairing the integrity of the type of protection are identified
3 Record inspection results
- 3.1Defects identified by visual and close inspection are recorded in accordance with inspection standards and site record systems
- 3.2Documentation in relation to all aspects of the inspection is forwarded to the authorised person for inclusion in the verification dossier
Performance evidence
- preparing to conduct a visual and close inspection of electrical installations for gas and dust hazardous areas, including: reviewing safe work methods associated with the classified area in which the work is to be carried out
- preparing to conduct a visual and close inspection of electrical installations for gas and dust hazardous areas, including: determining the type and location of equipment subject to the inspection
- conducting visual and close inspections of electrical installations in gas and dust hazardous areas, including: obtaining interpreting and applying safe work methods
- conducting visual and close inspections of electrical installations in gas and dust hazardous areas, including: identifying defects impairing the integrity of the type of protection
- completing record of visual and close inspections of electrical installations in gas and dust hazardous areas, including: recording defects identified in the inspection impairing the integrity of the type of protection
- completing record of visual and close inspections of electrical installations in gas and dust hazardous areas, including: forwarding the inspection record for inclusion in the verification dossier
Knowledge evidence
- purpose, scope and limitations of visual and close inspections, including:
- inspection program for the site based on schedules specified in inspection standards
- periodic inspection schedules covering equipment, installations and environment for:
- flameproof - Ex ‘d’
- increased safety - Ex ‘e’
- non-sparking - Ex ‘n’
- intrinsic safety - Ex ‘i’
- intrinsic safety - Ex ‘iD’
- non-sparking - Ex ‘nL’
- pressurisation - Ex ‘p’
- pressurisation - Ex ‘pD’
- protection by enclosure - Ex ‘tD’
- aspects of close and visual inspections, including:
- items subject to visual and close inspection listed in schedules specified in inspection standards
- defects impairing the integrity of the type of protection that can be identified by visual and close inspection, including:
- excessive corrosion
- missing cover and mounting bolts
- enclosure or cable damage
- non-secured cables
- exposed armouring/cable cores at glanding points
- missing or illegible labels
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEEHA0038
What does an assessment tool for UEEHA0038 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEEHA0038 needs to address all 35 unit components: 3 elements with 8 performance criteria, 6 performance evidence requirements, 21 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEEHA0038?
Auditori pulls the current release of UEEHA0038 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEEHA0038 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEEHA0038 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEEHA0038, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEEHA0004 — Enter a classified hazardous area to undertake work related to electrical equipment
- UEEHA0008 — Design gas detection systems
- UEEHA0016 — Assess the fitness-for-purpose of explosion-protected equipment
- UEEHA0017 — Classify areas where a combustible dust hazard may arise
- UEEHA0018 — Classify areas where flammable gas or vapour hazards may arise
- UEEHA0019 — Conduct a conformity assessment review of explosion-protected equipment
- UEEHA0020 — Conduct detailed inspection of electrical installations for hazardous areas
- UEEHA0021 — Design explosion-protected electrical systems and installations
- UEEHA0022 — Determine the explosion-protection requirements to meet a specified classified hazardous area
- UEEHA0023 — Develop and manage periodic electrical inspection and maintenance programs for hazardous areas
- UEEHA0024 — Inspect, maintain and fit plugs/couplers for reeling, trailing and flexible cables - coal mining
- UEEHA0025 — Install explosion-protected equipment and associated apparatus and wiring systems
Your UEEHA0038 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEEHA0038 free