UEEHA0020 — Conduct detailed inspection of electrical installations for hazardous areas
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEEHA0020 must cover
22 assessable components: 3 elements (16 performance criteria), 3 performance evidence and 3 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare for inspection
- 1.1WHS/OHS procedures and safe work methods are reviewed in preparation to work in a classified hazardous area
- 1.2Knowledge of the scope of detailed inspections specified in inspection standards and site inspection program is applied to work preparation
- 1.3Classification of the area is ascertained from hazardous area layout drawings retained in the verification dossier
- 1.4Type and grade of inspection is ascertained from the inspection schedule retained in the verification dossier
- 1.5Classification details and specified location of each item of equipment and circuits subject to inspection are determined from design drawings and equipment certification documentation retained in the verification dossier
- 1.6Special tools, equipment and testing devices needed to carry out the inspection are checked to ensure they are safe and serviceable, and any defective items are either rectified or replaced
2 Conduct inspection
- 2.1Safe work methods relating explosive atmospheres and inspections, including isolation of equipment, are obtained and applied
- 2.2Knowledge of the explosion-protection aspects of equipment and hazardous area installation requirements is applied
- 2.3Equipment, systems and installation are inspected for compliance with the design specifications retained in the verification dossier and in accordance with the inspection schedule and standards
- 2.4Where applicable in a given jurisdiction, an appropriately authorised person is directed to remove equipment enclosure covers and internal components, where needed, to enable inspection
- 2.5Arrangements are made to store and protect equipment covers and components that are removed to enable inspection
- 2.6Where applicable in a given jurisdiction, after the inspection of each item, an appropriately authorised person is directed to replace equipment covers and components in a manner that ensures the integrity of the explosion-protection system
3 Record results of detailed inspection
- 3.1Results of inspection are recorded in accordance with inspection standards
- 3.2Defects such as equipment deterioration, faults and unauthorised modifications are recorded in accordance with inspection standards
- 3.3Actions to rectify defects are specified in the inspection record
- 3.4The inspection record is forwarded to the appropriate personnel for inclusion in the verification dossier in accordance with inspection standards
Performance evidence
- preparing to conduct a detailed inspection of the electrical installation, including: - reviewing safe work methods associated with the classified area in which the work is to be carried out - determining the scope of inspection, including: - ascertaining the area classification from hazardous area layout drawings retained in the verification dossier - ascertaining the type and grade of inspection from the inspection schedule retained in the verification dossier - determining classification details and the specified location of each item of equipment and circuits subject to the inspection from design drawings and equipment certification documentation retained in the verification dossier - checking safety and serviceability of special tools, equipment and testing devices needed to carry out the inspection
- conducting detailed inspections of the electrical installation encompassing: - accepting and following safe work methods relating to the work - carrying out the detailed inspection to requirements, including: - conducting detailed inspections for compliance with design specifications and in accordance with inspection schedules and standards - making arrangements to store and protect parts of equipment dismantled in order to conduct inspection - where applicable in a given jurisdiction, directing an authorised person to: - disconnect and dismantle equipment as necessary to conduct the inspection - reconnect and reassemble equipment in a manner that ensures the integrity of the explosion-protection system after equipment is inspected
- completing records of detailed inspections of the electrical installation, including: - recording the results of the detailed inspection including equipment deterioration, faults and unauthorised modifications - specifying actions to rectify defects found in the inspection - forwarding the inspection record for inclusion in the verification dossier
Knowledge evidence
- safe work procedures for explosive atmospheres, including: - Work health and safety (WHS)/occupational health and safety (OHS) procedures for working in hazardous areas - permit to work systems that cover the hazardous aspects of specific work and location
- scope and aspects of detailed inspections, including: - inspection program for the site based on schedules specified by inspection standards - periodic inspection schedules covering equipment, installations and environment for: - Ex ‘d’, Ex ‘e’ and Ex ‘n’ installations - Ex ‘i’, Ex ‘iD’ and Ex ‘nL’ installations - Ex ‘p’ and Ex ‘pD’ - Ex ‘t’ - specific aspects of initial inspections including ensuring: - equipment is appropriate to the equipment protection level (EPL)/zone requirements of the location - equipment group is correct - equipment maximum surface temperature is correct - equipment circuit identification - cable gland - type of cable - sealing - fault-loop impedance or earthing resistance - overload protection - additional aspects of initial inspection schedule requirements for types of protection: - ‘d’ – flameproof enclosure - ‘e’ – increased safety - ‘i’ and ‘iD’ – intrinsic safety - ‘p’ and ‘pD’ – pressurised enclosure - ‘n’ - non-sparking enclosure - ‘t’ – protection by enclosure - ‘m’ and ‘mD’ -encapsulation - ‘o’ oil-immersion - ‘q’ powder-filling - ‘v’ – ventilation - ‘p’ – pressurisation — rooms
- requirements for installing equipment and wiring systems for explosive atmospheres, including: - required documentation - installation requirements for protection from dangerous (incendive) sparking, including: - earthing system requirements - SELV and PELV systems - electrical separation - limitation of equipment installed above a hazardous area - requirements for potential equalisation, including: - various earthing systems - bonding systems - cable armour and screens - exposed conductive parts - metallic enclosures - cathodic protection - temporary bonding - wiring systems, including: - limitation on the use of aluminium conductors - fixed cable and wiring systems permitted for Groups I, II and III - wiring systems permitted and not permitted in or above hazardous areas - cables supplying transportable and portable equipment - flexible connections and flexible cables - connection to equipment, including: - cable glands and blanking elements per enclosure type - non-electrical entries - conduit systems - termination of conductors - treatment of unused core - unused opening/entries in enclosures - joining cables - openings in walls - passage and collection of flammables - additional requirements for each type of explosion protection - cable and conduit termination devices and techniques, including: - cable glands, conduits and sealing: - types of glands and components - requirements for fitting glands and applying sealing compound - requirements for conduit seals and applying sealing compound
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEEHA0020
What does an assessment tool for UEEHA0020 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEEHA0020 needs to address all 22 unit components: 3 elements with 16 performance criteria, 3 performance evidence requirements, 3 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEEHA0020?
Auditori pulls the current release of UEEHA0020 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEEHA0020 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEEHA0020 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEEHA0020, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEEHA0004 — Enter a classified hazardous area to undertake work related to electrical equipment
- UEEHA0008 — Design gas detection systems
- UEEHA0016 — Assess the fitness-for-purpose of explosion-protected equipment
- UEEHA0017 — Classify areas where a combustible dust hazard may arise
- UEEHA0018 — Classify areas where flammable gas or vapour hazards may arise
- UEEHA0019 — Conduct a conformity assessment review of explosion-protected equipment
- UEEHA0021 — Design explosion-protected electrical systems and installations
- UEEHA0022 — Determine the explosion-protection requirements to meet a specified classified hazardous area
- UEEHA0023 — Develop and manage periodic electrical inspection and maintenance programs for hazardous areas
- UEEHA0024 — Inspect, maintain and fit plugs/couplers for reeling, trailing and flexible cables - coal mining
- UEEHA0025 — Install explosion-protected equipment and associated apparatus and wiring systems
- UEEHA0026 — Maintain equipment associated with hazardous areas
Your UEEHA0020 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEEHA0020 free