MEM48009Undertake and interpret results of chemical analysis on metal samples

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for MEM48009 must cover

39 assessable components: 5 elements (20 performance criteria), 9 performance evidence and 10 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Determine job requirements

  • 1.1Follow standard operating procedures (SOPs)
  • 1.2Comply with work health and safety (WHS) requirements at all times
  • 1.3Use appropriate personal protective equipment (PPE) in accordance with SOPs
  • 1.4Identify job requirements from work information

2 Organise required test(s)

  • 2.1Identify information and required test data
  • 2.2Select appropriate test(s) which will yield the required data
  • 2.3Determine the capacity to undertake required test(s)
  • 2.4Confirm capacity to undertake test(s) with selected body
  • 2.5Arrange for testing to be carried out in accordance with SOPs

3 Undertake optical emission spectroscopy

  • 3.1Prepare sample by test method according to testing requirements
  • 3.2Prepare instrument in accordance with procedures using required tools and equipment
  • 3.3Test sample in accordance with test instructions
  • 3.4Record and check test results and repeat based on test outcomes

4 Interpret test results

  • 4.1Check test results are within the expected range and take appropriate action for non-conforming results
  • 4.2Perform any required calculations or test data manipulations
  • 4.3Determine implications of test results for process and/or product
  • 4.4Develop actions to be taken based on test results

5 Implement actions

  • 5.1Communicate required actions to relevant personnel
  • 5.2Follow through on communication to check implementation
  • 5.3Check results of actions and follow up based on requirements

Performance evidence

  • Following work instructions, standard operating procedures and safe work practices
  • Identifying relevant spectra
  • Communicating both with other technicians and also with shop floor operatives about technical matters
  • Writing technical reports and production specifications
  • Understanding and interpreting numeric data as well as manipulating test data in order to obtain the required information
  • Calculating concentrations and dilutions
  • Applying mathematics relevant to the manipulation and interpretation of test data
  • Applying knowledge of the impact of chemical composition on the foundry process and product and what adjustments should be made, and how they can be made
  • Implementing, checking results of actions and following up, as required

Knowledge evidence

  • Safe work practices and procedures and use of Personal Protective Equipment (PPE)
  • Principles of operation, uses and limitations of: Optical Emission Spectroscopy (OES) (otherwise known as Atomic Emission Spectroscopy (AES))
  • Principles of operation, uses and limitations of: UV - Visible Spectrophotometry (UV Vis)
  • Principles of operation, uses and limitations of: Infrared Spectroscopy (IR)
  • Principles of operation, uses and limitations of: Gas Chromatography (GC)
  • Principles of operation, uses and limitations of: X-Ray Fluorescence (XRF)
  • Principles of operation, uses and limitations of: Flame Photometry
  • Principles of operation, uses and limitations of: Atomic Absorption Spectrometry (AAS)
  • Principles of operation, uses and limitations of: Scanning Electron Microscopy (SEM)
  • Traditional Wet Analysis

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing MEM48009

What does an assessment tool for MEM48009 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for MEM48009 needs to address all 39 unit components: 5 elements with 20 performance criteria, 9 performance evidence requirements, 10 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for MEM48009?

Auditori pulls the current release of MEM48009 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for MEM48009 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing MEM48009 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of MEM48009, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.