MEM27006Diagnose and rectify batteries, low voltage sensors and circuits

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for MEM27006 must cover

59 assessable components: 4 elements (24 performance criteria), 13 performance evidence and 22 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Determine job requirements

  • 1.1Follow standard operating procedures (SOPs)
  • 1.2Comply with work health and safety (WHS) requirements at all times
  • 1.3Use appropriate personal protective equipment (PPE) in accordance with SOPs
  • 1.4Identify job requirements from specifications, drawings, job sheets or work instructions

2 Use test instruments

  • 2.1Apply principles of electron theory, current, voltage and resistance to diagnose and rectify low voltage electrical systems
  • 2.2Select, use and maintain appropriate test instruments to determine current, voltage and resistance
  • 2.3Interpret electrical drawings and manufacturer diagrams
  • 2.4Determine series, parallel and series parallel circuits
  • 2.5Interpret and apply basic electrical laws
  • 2.6Connect amps voltage and resistance (AVR) test instruments into circuits to measure current, voltage and resistance
  • 2.7Read meters to standard accuracy
  • 2.8Use and apply multipliers and shunts

3 Test battery

  • 3.1Interpret and apply chemical battery operating principles when testing batteries
  • 3.2Determine electrolyte level and record specific gravity readings temperature
  • 3.3Carry out dry charge preparation and recharging of batteries
  • 3.4Perform discharge testing according to prescribed procedures
  • 3.5Select replacement batteries for application

4 Assess and rectify wiring faults

  • 4.1Isolate wiring and sensor fault
  • 4.2Determine replacement sensors and cables/wires, including size and insulation quality
  • 4.3Make up wiring looms for application and securely fix
  • 4.4Strip, fit, prepare and terminate wiring and cables
  • 4.5Test terminated cables for continuity and to comply with requirements
  • 4.6Remove corrosion, neutralise and apply appropriate protective coating
  • 4.7Test sensors, relays, solenoids, contacts and circuits and repair/replace

Performance evidence

  • following work instructions, standard operating procedures (SOPs) and safe work practices
  • identifying and interpreting specifications, charts, lists, SOPs, electrical drawings and diagrams to diagnose and rectify batteries, low voltage sensors and circuits
  • selecting and using the correct test instrument, including multimeters, amp meters and circuit testers, for a variety of electrical circuits to measure current, voltage and resistance of specified circuit components or sections of circuitry
  • applying Ohm’s Law to determine the required values of current, voltage and resistance of a range of electrical circuits, including series, parallel and series parallel
  • connecting electrical test instruments into given circuits to determine the required values of current, voltage and resistance in a safe and effective manner
  • determining the specific gravity of the electrolyte for temperature variations using a hydrometer
  • preparing dry batteries for charging and recharging and performing discharge testing of batteries
  • fault finding using fault-finding techniques to identify wiring faults in electrical circuits
  • selecting appropriate replacement cables according to size, rating and insulation resistance from supplier catalogues
  • making up replacement wiring looms, stripping and preparing cable ends for termination and terminating to specifications
  • testing terminations for continuity and compliance with requirements
  • removing and/or neutralising corrosion from terminals and connections and applying appropriate protective coating
  • testing and fault finding a range of circuits components, including sensors, relays, solenoids, contacts for repair/replacement.

Knowledge evidence

  • safe work practices and procedures and use of personal protective equipment (PPE)
  • principles of electron theory
  • definitions of current, voltage and resistance in terms of electrical circuits
  • Ohm’s Law and the relationships between current, voltage and resistance for a variety of given electrical circuits
  • instruments and procedures to be used to measure current, voltage and resistance and safety precautions to be taken
  • procedures for maintaining electrical test equipment
  • function of a variety of electrical circuits identified from given electrical drawings/diagrams
  • symbols used in electrical drawings/diagrams
  • components of a variety of electrical circuits identified by given electrical drawings/diagrams
  • differences between series and parallel electrical circuits
  • function of a general purpose oscilloscope and procedures for connecting a general purpose oscilloscope into given electrical circuits
  • use of wave forms in the testing of electrical circuits
  • accuracy to which a range of electrical test equipment can be read
  • procedures for: using multipliers and shunts in the measurement of electrical circuits; measuring the specific gravity of the electrolyte and the effect of temperature on the specific gravity of the electrolyte; preparing and recharging dry batteries; discharge testing of batteries and purpose; making up and fixing wiring looms can be given; stripping, fitting and preparing wiring terminations; soft and hard soldering/crimping of wiring terminations; corrosion removal and/or neutralisation
  • operation of a chemical battery and the function of the electrolyte in batteries and specifications applied to batteries
  • examples and causes of common faults in electrical wiring and test procedures for isolating wiring faults
  • specifications of cables and wires, including insulation resistance used in given electrical circuits
  • test procedures for terminated wiring and cables
  • effect of corrosion on the performance of electrical circuits and connections
  • coatings available to stop/inhibit corrosion
  • correct operational principles of sensors, relays, solenoids and contacts
  • common faults and causes in sensors, relays, solenoids, contacts and circuits and procedures for testing circuit components.

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing MEM27006

What does an assessment tool for MEM27006 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for MEM27006 needs to address all 59 unit components: 4 elements with 24 performance criteria, 13 performance evidence requirements, 22 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for MEM27006?

Auditori pulls the current release of MEM27006 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for MEM27006 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing MEM27006 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of MEM27006, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your MEM27006 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate MEM27006 free