MEM24033Undertake thermography tests

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for MEM24033 must cover

96 assessable components: 4 elements (16 performance criteria), 12 performance evidence and 68 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Establish job requirements

  • 1.1Comply with relevant WHS and regulatory requirements, standards, codes of practice and standard operating procedures (SOPs) for thermography testing
  • 1.2Identify job requirements from customer specifications, job sheets or work instructions

2 Prepare for thermographic testing

  • 2.1Liaise with client to explain testing requirements and schedule tests
  • 2.2Use established safe work practices and personal protective equipment (PPE) in accordance with SOPs
  • 2.3Identify test material inspection area determine if special access requirements appropriate for the NDT test need to be communicated to the client
  • 2.4Clean and prepare inspection areas for testing using appropriate procedures
  • 2.5Check and prepare all test equipment in accordance with manufacturer’s specifications and job specification

3 Perform thermographic testing

  • 3.1Select the most appropriate thermographic test for the material and/or application
  • 3.2Set up test equipment in accordance with relevant standards and job specifications
  • 3.3Carry out thermographic test in accordance with relevant standards and specifications
  • 3.4Check thermographic testing equipment for defects, and maintain and store in accordance with procedures and manufacturer instructions

4 Interpret and report the results of thermographic tests

  • 4.1Review conduct of the test and confirm test procedures were applied correctly
  • 4.2Process thermographic images in accordance with standards and codes and job specifications
  • 4.3Determine material condition and defects according to standards and codes and job specification acceptance criteria
  • 4.4Report test results in accordance with enterprise procedures, accepted industry practices and job specifications
  • 4.5Store and catalogue thermal images for later comparative analysis

Performance evidence

  • follow work instructions, standard operating procedures (SOPs) and safe work practices
  • identify and interpret specifications, relevant testing standards, codes and other reference documentation for performing thermographic testing.
  • prepare work areas and materials for thermographic testing
  • adjust thermographic testing settings and techniques for environment conditions and ambient temperature
  • select appropriate thermography techniques for at least three different materials and test specifications
  • undertake numerical operations and calculations associated with performing thermographic testing
  • perform the following thermographic tests on different materials and prepare a report for each test according to non-destructive standard and code requirements:
  • lock-in thermographic test (periodic excitation method)
  • pulse thermographic test
  • transient thermographic test
  • continual excitation thermographic test.
  • Note: Where a volume and/or frequency is not specified, demonstration must be provided at least once.

Knowledge evidence

  • Evidence required to demonstrate the required knowledge for this unit must be relevant to and satisfy the requirements of the elements and performance criteria and include knowledge of standards and codes relevant to non-destructive testing
  • applications and limitations of thermographic non-destructive testing for:
  • detection of defects in materials including cracks, cavities, voids, and inhomogeneities
  • inspection of welded joints
  • determination of material internal structure
  • detection of contaminants
  • condition monitoring
  • electromagnetic spectrum and wavelength ranges for infra-red, visible light, ultra-violet, X-ray and gamma ray
  • principles of heat and heat transfer including:
  • heat as energy
  • temperature scales
  • phases
  • heat transfer – conduction, convection and radiation including:
  • Fourier’s law
  • Newton’s law of cooling
  • evaporation fundamentals
  • principles of infra-red radiation including:
  • natural and artificial sources of infra-red radiation
  • principles related to emission, reflection, transmission and absorption of infra-red radiation
  • black body, grey body and selective radiators
  • Plank’s law
  • Wien’s law
  • Stefan-Boltzmann law
  • Kirchoff’s radiation law
  • cavity radiation effect
  • thermal property of materials including:
  • emissivity
  • reflectance
  • transmittance
  • effects of surface structure and coating
  • methods of temperature measurement
  • qualitative thermography including:
  • definition
  • advantages and disadvantages
  • typical applications in manufacturing and engineering
  • equipment and test techniques
  • quantitative thermography including:
  • definition
  • effects of temperature and the environment
  • advantages and disadvantages
  • typical applications in manufacturing and engineering
  • equipment and test techniques
  • difference between passive and active thermography
  • principles of excitation including:
  • sources
  • type of excitation – pulse, periodic or continuous
  • thermographic image capture including:
  • infra-red cameras including high-speed cooled infra-red cameras, lenses and other accessories
  • bolometers and other sensors
  • equipment factors affecting thermographic image capture including:
  • sensitivity
  • imager field of view
  • imager smallest identifiable object
  • imager smallest measurable object
  • emissivity of test material
  • focus
  • duration
  • temperature range setting
  • environment and temperature of test area
  • speed of response
  • frame repetition rate
  • thermographic image analysis techniques including:
  • lock-in
  • motion compensation
  • background and other subtractions
  • data selection criteria according to job type and standards, codes and procedures
  • use of image analysis software
  • thermographic image post-processing techniques.

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing MEM24033

What does an assessment tool for MEM24033 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for MEM24033 needs to address all 96 unit components: 4 elements with 16 performance criteria, 12 performance evidence requirements, 68 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for MEM24033?

Auditori pulls the current release of MEM24033 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for MEM24033 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing MEM24033 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of MEM24033, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your MEM24033 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate MEM24033 free