MEM10020 — Install low voltage cabling and fit-off accessories, appliances and equipment
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for MEM10020 must cover
124 assessable components: 4 elements (21 performance criteria), 19 performance evidence and 84 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Determine job requirements
- 1.1Follow standard operating procedures (SOPs)
- 1.2Comply with work health and safety (WHS) requirements at all times, including appropriate risk control measures
- 1.3Use appropriate personal protective equipment (PPE) in accordance with SOPs
- 1.4Identify job requirements from specifications, drawings, job sheets or work instructions
2 Plan installation of electrical wiring, accessories and appliances
- 2.1Plan cable routes in accordance with requirements contained in the job instructions/specifications
- 2.2Obtain necessary cables, appropriate cable support systems and enclosures, accessories and appliances needed for the installation work in accordance with established procedures and check against job requirements
- 2.3Obtain necessary tools, equipment and testing instruments needed for the installation work
3 Install and fit off electrical wiring, accessories and appliances
- 3.1Isolate and tag circuits and equipment in accordance with procedures, where required
- 3.2Install and fix cable support system in position ensuring components are square and plumb, securely attached using fastenings appropriate to the weight of the components and the material of the mounting
- 3.3Install electrical cables and wiring, accessories and appliances in compliance with specifications and regulatory requirements
- 3.4Maintain fire integrity when installing electrical cables and wiring
- 3.5Check installed accessories and appliances are straight and square in the required locations
- 3.6Terminate cables and conductors at switchboards, accessories and appliances in accordance with manufacturer specifications and regulatory requirements
- 3.7Test and inspect installed circuits to ensure compliance in accordance with legislative and regulatory requirements
- 3.8Rectify any defects and re-test to ensure compliance
- 3.9Document installation of wiring, accessories and appliances in accordance with SOPs
4 Connect consumers mains to an installation
- 4.1Install underground and overhead consumers mains
- 4.2Install unprotected consumers mains to reduce the risk of short circuit to a minimum
- 4.3Terminate consumers mains at pillars, pits, mains connection boxes and consumers switchboard
- 4.4Install bonding conductors, where required
- 4.5Ensure correct polarity
Performance evidence
- following work instructions, standard operating procedures (SOPs) and safe work practices
- identifying and interpreting circuits, drawings, plans and specifications relevant to the work to be undertaken
- planning the cable routes in accordance with legislative and customer requirements
- installing cable support systems
- complying with the following cable support system requirements:
- bending steel conduits (where applicable) such that the internal diameter is not significantly reduced
- preparing entry joints and joints to ensure cable insulation is not damaged
- joining steel conduits together using appropriate accessories or if required through a welding process
- ensuring that they are adequately sealed against entry of water or rain
- installing wiring systems using applicable cable support systems according to the electrical installation requirements and standards paying particular attention to factors effecting cable current-carrying capacity
- maintaining fire integrity
- terminating cables and conductors to switchboard protective devices
- terminating cables and conductors at switchboards, accessories and appliances according to legislative, regulatory and manufacturer requirements
- installing all accessories, appliances and equipment square and straight and in the required location using appropriate hand and power tools
- ensuring appropriate Ingress Protection (IP) rating when selecting suitable electrical equipment
- inspecting and testing installed and terminated cables to ensure they comply with continuity and insulation resistance and are safe to connect to the supply
- rectifying any defects and retesting to ensure compliance
- connecting and terminating consumers mains to an installation
- completing appropriate documentation in accordance with SOPs.
Knowledge evidence
- safe work practices and procedures and use of personal protective equipment (PPE)
- Australian Standards, codes and requirements applicable to the installation for:
- thermoplastic sheathed (TPS - flat and circular) and thermoplastic insulated (TPI) cables
- fire protection and mineral insulated metal sheathed (MIMS) cables
- steel wired armoured (SWA)
- flexible cords used as fixed wiring
- trailing cable and catenary wire systems
- cables support systems
- protection against mechanical damage
- wiring systems likely to be disturbed
- wiring systems installed vertically
- change of direction
- prohibited cable locations
- selection and installation to minimise the spread of fire
- limitation of circulating and eddy currents
- Australian/New Zealand Wiring Rules requirements for enclosure of cables, including:
- types of wiring enclosures – change of wiring enclosures, entry of water and support of cables
- installation of wiring enclosures – support, continuity, bending, passage of conductors, terminations, in direct sunlight, provision for expansion and cable trunking
- factors effecting cable current-carrying capacity
- dissimilar metals in a corrosive environment
- application of protective coatings, e.g. paint, galvanizing and powder coatings
- techniques, tools and equipment required to install conduit (metallic and non-metallic), enclosures and support systems
- Australian Standards, codes and requirements applicable to the installation of electrical equipment, including:
- appliances
- switchgear, controlgear and accessories
- switchboards – location and access, physical and circuit arrangements
- socket outlets
- lighting equipment and accessories, lamps and luminaires
- smoke and fire detectors
- cooking appliances
- appliances producing hot water or steam
- room, space and duct heaters
- electric heating cables for floors and ceilings
- electricity converters
- motors, transformers, capacitors and batteries
- control, switching and over current and residual current device (RCD) protection
- required and permitted locations for current-using equipment and accessories
- suitable IP rating
- correct marking of equipment
- terminal configuration of phase, neutral and protective earthing conductors for each type of equipment
- installation standards called up by the Australian/New Zealand Wiring Rules for special situations, including:
- movable premises and caravan parks
- shows and carnivals
- boating marinas
- electromedical treatment areas
- outdoor sites under heavy conditions
- cranes and hoists
- lifts
- cold cathode illumination systems
- electric fences
- construction and demolition sites
- film, video and television sites
- telecommunications networks power supplies
- hazardous areas e.g. AS/NZS 2430:2004 Classification of hazardous areas, AS/NZS 2381 Set:2008 Electrical equipment for explosive gas atmospheres – Selection, installation and maintenance Set (or their equivalent updated versions)
- Australian/New Zealand Wiring Rules requirements for special electrical installations or locations, including:
- baths, showers or other fixed water containers
- swimming pools, paddling pools and spa pools or tubs
- sauna heaters
- refrigeration rooms
- locations where water general hosing down operations are carried out
- fountains and water features
- extra-low voltage electrical installations
- high voltage electrical installations
- hazardous areas
- emergency systems
- additional training required to work competently with electrical equipment for hazardous areas
- underground wiring systems, including:
- arrangements and installation requirements
- spacing from other underground services
- consumer mains
- aerial wiring systems, including:
- types of conductor
- arrangements, clearances, distance between supports (spans), aerial conductor supports, poles and posts and joints and connections
- Australian/New Zealand Wiring Rules and local supply authority requirements
- testing of installed cables in compliance with Australian Standards
- cables supported by catenary, including:
- types of cables
- catenary supports
- tools, techniques and procedures for installing cables and wiring systems
- testing and verification of installed and terminated cables to ensure they comply with a visual inspection, all mandatory and optional tests and are safe to connect to the supply
- installation of underground and overhead consumer mains
- termination of consumer mains at pillars, pits, mains connection boxes and consumers switchboard
- installation of unprotected consumers mains to reduce the risk of short circuit to a minimum
- installation of bonding conductors, where required.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing MEM10020
What does an assessment tool for MEM10020 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for MEM10020 needs to address all 124 unit components: 4 elements with 21 performance criteria, 19 performance evidence requirements, 84 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for MEM10020?
Auditori pulls the current release of MEM10020 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for MEM10020 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing MEM10020 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of MEM10020, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- MEM03001 — Perform manual production assembly
- MEM03002 — Perform precision assembly
- MEM03003 — Perform sheet and plate assembly
- MEM03004 — Perform electronic/electrical assembly (production)
- MEM03005 — Rework and repair (electrical/electronic production)
- MEM03006 — Set assembly stations
- MEM04001 — Operate melting furnaces
- MEM04002 — Perform gravity die casting
- MEM04003 — Operate pressure die casting machine
- MEM04004 — Prepare and mix sand for metal moulding
- MEM04006 — Operate sand moulding and core making machines
- MEM04007 — Pour molten metal
Your MEM10020 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate MEM10020 free