UETDRDS023Draft and layout distribution substation minor upgrade

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for UETDRDS023 must cover

28 assessable components: 3 elements (14 performance criteria), 8 performance evidence and 6 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Prepare to draft and layout distribution substation minor upgrade

  • 1.1Project requirements are determined
  • 1.2Draft and layout specifications are determined in accordance with workplace requirements
  • 1.3Tools, equipment and personal protective equipment (PPE) required for site inspections are determined, obtained and confirmed in working order
  • 1.4Requirements for site inspections are determined in accordance with workplace requirements
  • 1.5Work is prioritised and sequenced for completion in accordance with workplace requirements

2 Draft and layout distribution substation minor upgrade

  • 2.1Site inspection is performed
  • 2.2Substation minor upgrade is drafted and laid out in accordance with workplace requirements
  • 2.3Systems modelling is used to evaluate and determine best outcomes in accordance with workplace requirements
  • 2.4Sustainable energy principles are used to evaluate and determine best outcomes in accordance with workplace requirements
  • 2.5Draft and layout are checked for compliance against legislation, regulations, standards and codes of practice
  • 2.6Health and safety risks are identified and minimised or eliminated by using safety and control measures in the draft and layout process
  • 2.7Quality checks of work are undertaken in accordance with workplace requirements

3 Complete work and documentation

  • 3.1Completed work is checked against project and workplace requirements
  • 3.2Work records, reports and documentation are completed, approved and appropriate personnel notified in accordance with workplace requirements

Performance evidence

  • drafting and laying out of distribution substation minor upgrade, including: specifications, requirements for site inspection, systems modelling to evaluate and determine best outcomes, sustainable energy principles and practices, compliance against legislation, regulations, standards and codes of practice, project and workplace requirements, identifying, minimising or eliminating health and safety risks by using safety and control measures, obtaining, inspecting and using relevant personal protective equipment (PPE) for site inspection, prioritising and sequencing work for completion in accordance with workplace requirements
  • drafting at least one (1) of the following: a multi-phase pole mounted distribution transformer upgrade layout, a single-phase pole mounted transformer upgrade
  • drafting the layout of at least one (1) of the following: a multi-phase underground distribution substation upgrade, a multi-phase distribution substation or associated equipment upgrade
  • completing all of the following for each of the completed drafts: single line diagram, above ground layout diagram, below ground layout diagram, earthing layout diagram, primary plant dimensioning checklist, standards compliance checklist
  • performing at least one (1) site inspection
  • performing ongoing quality checks of work in accordance with workplace requirements
  • checking final design against project and workplace requirements
  • completing relevant work records, reports and documentation

Knowledge evidence

  • distribution substation minor upgrade, draft and layout, including: project requirements, design specifications, hazard, risk assessment and risk control requirements, including potential hazards, types and application of PPE, site inspections, use of systems modelling for best outcomes, application of sustainable energy principles and practices, compliance with legislation, regulations, standards, codes of practice, and project and workplace requirements, work records, reports and documentation
  • distribution substations, including: pole mounted transformers, pad mounted transformers, overhead conductors, route length and connections, underground cables, joints and terminations, high voltage (HV)/low voltage (LV) switchgear, substation construction types, structures and clearances
  • manuals, diagrams and drawings, including: distribution extensions, distribution substations, street lighting systems, switching symbols and operations, mechanical drawings
  • principles of surveying, including: buried services detection, techniques for measuring heights and distances, pegging
  • principles of cabling and trenching
  • principles of computer-aided drafting

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UETDRDS023

What does an assessment tool for UETDRDS023 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UETDRDS023 needs to address all 28 unit components: 3 elements with 14 performance criteria, 8 performance evidence requirements, 6 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UETDRDS023?

Auditori pulls the current release of UETDRDS023 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UETDRDS023 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UETDRDS023 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UETDRDS023, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your UETDRDS023 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate UETDRDS023 free