UEPOPS093 — Operate and monitor flue gas (NOx) mitigation systems
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEPOPS093 must cover
40 assessable components: 6 elements (18 performance criteria), 14 performance evidence and 8 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Plan and prepare work
- 1.1Work health and safety (WHS)/occupational health and safety (OHS) regulations, legislative requirements, codes of practice, manufacturers’ recommendations and specifications, environmental requirements and workplace procedures are identified, applied and monitored
- 1.2Work requirements, including permits, are identified from relevant personnel and documentation in accordance with workplace procedures
- 1.3Inspection, preoperational checks and preparations for NOx mitigation service are carried out in accordance with manufacturers’ recommendations and specifications, and workplace procedures
- 1.4NOx mitigation plant operational prerequisites are established in accordance with manufacturers’ recommendations and specifications, and workplace procedures
- 1.5Sequence for recommissioning of NOx mitigation plant is determined to suit existing circumstances in accordance with workplace procedures
2 Operate NOx mitigation plant
- 2.1NOx mitigation plant is operated in accordance with manufacturers’ recommendations and specifications, and workplace procedures
- 2.2NOx mitigation plant is monitored and observed to detect deviations from normal operating conditions in accordance with workplace procedures
- 2.3Corrective actions are taken to rectify NOx mitigation abnormalities in accordance with workplace procedures
3 Test NOx mitigation plant operation
- 3.1Operational tests are performed in accordance with workplace procedures
- 3.2NOx mitigation plant is observed for correct operational response in accordance with workplace procedures
- 3.3NOx mitigation plant is returned to required operational status upon completion of test in accordance with workplace procedures
4 Analyse NOx mitigation plant faults
- 4.1Causes of abnormal NOx mitigation plant operating conditions are identified by analysing technical and operational information in accordance with workplace procedures
- 4.2NOx mitigation plant integrity and personnel safety is maintained in consultation with relevant personnel and technical and operational documentation in accordance with workplace procedures
5 Monitor and inspect NOx mitigation plant
- 5.1NOx mitigation plant to be monitored and inspected is physically identified in accordance with workplace procedures
- 5.2NOx mitigation plant is monitored and inspected for normal operation and to detect deviations in accordance with workplace procedures,
- 5.3Relevant personnel are notified when defects are detected in accordance with workplace procedures
6 Complete documentation
- 6.1NOx mitigation plant problems, movements and status are reported in accordance with workplace procedures
- 6.2Documentation is updated in accordance with workplace procedures
Performance evidence
- analysing NOx mitigation plant faults using data analysis techniques and tools
- applying work health and safety (WHS)/occupational health and safety (OHS) requirements, including: emergency procedures, risk control measures, safe working practices
- communicating with personnel
- completing documentation using recording procedures
- identifying NOx mitigation plant status
- implementing regulations, legislative requirements, codes of practice, manufacturers’ recommendations and specifications, and environmental requirements
- interpreting manuals
- monitoring and inspecting NOx mitigation plant
- operating NOx emission control plant and equipment
- organising resources
- preparing NOx mitigation plant and equipment
- recognising and responding to abnormal flue gas (NOx) mitigation plant operating conditions
- testing NOx mitigation plant operation using diagnostic and testing techniques
- working with permit system
Knowledge evidence
- arrangements of power production plant
- manuals
- regulations, legislative requirements, codes of practice, manufacturers’ recommendations and specifications, and environmental requirements
- NOx mitigation system plant and equipment, location and operating parameters, including: NOx generation during combustion process within fossil fuelled boilers and gas turbines, NOx emission control plant and equipment components and the way they interact with plant and equipment, performance tests on NOx mitigation system plant
- permit system
- WHS/OHS requirements, including: emergency procedures, risk control measures, safe working practices
- workplace documentation
- workplace policies and procedures
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEPOPS093
What does an assessment tool for UEPOPS093 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEPOPS093 needs to address all 40 unit components: 6 elements with 18 performance criteria, 14 performance evidence requirements, 8 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEPOPS093?
Auditori pulls the current release of UEPOPS093 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEPOPS093 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEPOPS093 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEPOPS093, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEPOPS001 — Analyse single protection device operation
- UEPOPS002 — Apply environmental and sustainable energy procedures
- UEPOPS003 — Apply quality systems to work
- UEPOPS004 — Carry out operational checks on in-service electrical plant
- UEPOPS005 — Clean plant and equipment
- UEPOPS006 — Collect and analyse hydrological and meteorological data
- UEPOPS007 — Conduct chemical batching operations
- UEPOPS008 — Operate and monitor control room site in a multi-function environment
- UEPOPS009 — Conduct minor electrical maintenance
- UEPOPS010 — Conduct minor mechanical maintenance
- UEPOPS011 — Conduct multiple energy source isolation procedures for permit to work
- UEPOPS012 — Conduct non-routine operational testing
Your UEPOPS093 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEPOPS093 free