UEGNSG903 — Fault find and repair hydrogen storage equipment
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for UEGNSG903 must cover
96 assessable components: 3 elements (19 performance criteria), 42 performance evidence and 35 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Prepare to find and repair hydrogen storage equipment fault
- 1.1Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures for relevant work area are identified, obtained and applied
- 1.2Instructions for the work and relevant plans are obtained and confirmed with relevant person/s in accordance with workplace procedures and manufacturer instructions
- 1.3Nature of the fault is obtained from documentation and/or from relevant person/s to determine scope of work
- 1.4Relevant work permit/authorisations is obtained and confirmed with relevant person/s in accordance with job requirements and workplace procedures
- 1.5Location and access to equipment is organised and confirmed
- 1.6Appropriate equipment, tools, materials and personal protective equipment (PPE) required for the job are identified, obtained and checked for correct operation and safety in accordance with workplace procedures
- 1.7Site is prepared to minimise risk and damage to property, commerce and individuals in accordance with the job requirements and workplace procedures
- 1.8Appropriate person/s are communicated with and consulted to ensure work activity is coordinated effectively with person/s involved
2 Find and repair hydrogen storage equipment fault
- 2.1WHS/OHS risk control measures and policies and procedures are followed in accordance with workplace procedures
- 2.2Components are isolated, depressurised, purged, decommissioned, as necessary, in accordance with requirements and workplace procedures
- 2.3Service, fault finding, replacement or repairs of components are undertaken correctly and safely in accordance with level of responsibility, manufacturer instructions and workplace procedures
- 2.4Components are recommissioned, repressurised, purged as necessary, in accordance with requirements and workplace procedures
- 2.5Non-routine/unplanned events are referred to authorised person/s for directions in accordance with workplace procedures
- 2.6Quality and safety checks of the work are conducted in accordance with job requirements, workplace procedures and community and industry standards
3 Complete work and relevant documentation
- 3.1Work undertaken is checked for conformance and anomalies and proposed solutions reported to relevant person/s in accordance with workplace procedures
- 3.2Relevant records, reports and documentation are completed, processed and provided to appropriate person/s in accordance with workplace procedures
- 3.3Tools, equipment, components and any surplus resources/materials are cleaned, checked and securely stored and disposed of and returned, if necessary, in accordance with workplace procedures and manufacturer’s instructions
- 3.4Work site is rehabilitated/cleaned up and confirmed safe and secure in accordance with workplace procedures
- 3.5Notification of completion of work and tasks is communicated to relevant stakeholders in accordance with workplace procedures
Performance evidence
- applying relevant fault finding and repair techniques
- applying relevant work health and safety (WHS)/occupational health and safety (OHS) requirements, including:
- emergency response procedures
- sustainable energy and environmental principles and practices
- hazard identification and reporting
- hydrogen specific electrical hazard control measures and earth protection
- implementation of risk control measures
- selection and use of correct personal protective equipment (PPE)
- safely working with hazardous materials and equipment
- calibrating instruments used in performing tests and checks
- communicating with relevant stakeholders, including:
- authorised persons
- authorities
- qualified persons for the type of repair
- completing relevant reports and documentation
- complying with regulations, industry standards, legislative requirements, codes of practice, manufacturers’ recommendations and specifications, and environmental requirements
- dealing with unplanned events
- following workplace procedures, including:
- decommissioning and recommissioning procedures
- emergency shutdown procedures
- standard operating procedures
- interpreting relevant drawings, plans and material lists
- siolating systems
- obtaining and complying with relevant work permits
- performing tests and checks, including:
- corrosion inspections
- electrical checks
- filter checks, including differential pressure
- gas leak test
- inventory checks
- meter checks
- pressure and temperature checks
- status and condition checks on ancillary equipment
- visual inspections of relief vents
- recording relevant information
- shutting down operations and equipment
- using relevant equipment, including:
- electronic gas detection
- hand tools
- measuring equipment
- personal protective equipment (PPE)
- working safely in a hydrogen environment.
Knowledge evidence
- correct use of plant and equipment in a hydrogen environment, including:
- how to select appropriate equipment for tasks associated with hydrogen
- manufacturer specifications to make adjustments to parts where appropriate
- measuring equipment
- operating alarm and communication equipment
- operating hydrogen analysis equipment
- storage equipment, fitting, piping, and controls
- test equipment and its uses
- gas industry drawings, plans and material lists
- hydrogen physical and chemical characteristics
- hydrogen storage container pressure and capacity recommendations and limitations
- permit to work systems in a hydrogen environment
- regulations, industry standards, legislative requirements, codes of practice, manufacturers’ recommendations and specifications, and environmental requirements
- relevant safe work method statements (SWMS)/job safety assessments or risk mitigation processes
- relevant stakeholders, including:
- authorised persons
- authorities
- producers and users
- qualified persons for the type of repair
- relevant WHS/OHS legislated requirements, including:
- applicable emergency equipment and procedures
- hazards, risk assessment and control measures
- environmental and sustainable energy principles and practices, including:
- blue hydrogen
- brown hydrogen
- green hydrogen
- grey hydrogen
- relevant workplace documentation
- quality and safety checks
- relevant workplace policies and procedures, including:
- decommissioning and recommissioning procedures
- emergency shutdown procedures
- standard operating procedures
- techniques for fault finding and repairing equipment in a hydrogen storage facility
- technical drawings for the hydrogen environment.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing UEGNSG903
What does an assessment tool for UEGNSG903 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEGNSG903 needs to address all 96 unit components: 3 elements with 19 performance criteria, 42 performance evidence requirements, 35 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for UEGNSG903?
Auditori pulls the current release of UEGNSG903 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEGNSG903 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing UEGNSG903 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEGNSG903, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- UEGNSG002 — Apply environmental policies and procedures in the gas supply industry
- UEGNSG007 — Assess the operational capability of gas safety equipment on a delivery vehicle
- UEGNSG008 — Assist with the construction and laying of gas distribution mains
- UEGNSG009 — Assist with the construction, laying and connection of gas distribution services to mains
- UEGNSG010 — Conduct general excavations
- UEGNSG011 — Conduct isolations under the permit to work system for gas industry worksites
- UEGNSG012 — Construct and lay plastic gas distribution mains
- UEGNSG013 — Construct, lay and connect a gas distribution service to a main
- UEGNSG014 — Control industrial gas storage/processing operations
- UEGNSG015 — Coordinate gas transmission pipeline repairs and modifications
- UEGNSG016 — Establish right of way access and maintain transmission pipeline easement
- UEGNSG017 — Fill by weight industrial gas cylinders
Your UEGNSG903 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate UEGNSG903 free