UEEEC0026Enter and verify programs for fire protection systems

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for UEEEC0026 must cover

41 assessable components: 3 elements (17 performance criteria), 9 performance evidence and 15 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Prepare to enter operating instructions

  • 1.1Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures for a given work area are identified and applied
  • 1.2WHS/OHS risk control measures and procedures are followed in preparation for the work
  • 1.3Safety hazards that have not previously been identified are assessed, reported and advice on risk control measures sought from work supervisor
  • 1.4Extent of programming work is determined from job specifications and in consultation with appropriate person/s
  • 1.5Tools, equipment and testing devices needed to carry out fire protection work activities are obtained and checked for correct operation and safety
  • 1.6Fire protection device installation is checked for compliance with job specification, industry standards and regulations

2 Enter software operating instructions

  • 2.1WHS/OHS risk control measures and workplace procedures for carrying out the work are followed
  • 2.2Circuits/machines/plant are checked and isolated in accordance with WHS/OHS requirements and workplace procedures
  • 2.3Status of each function of the fire protection device is entered and their parameters set in accordance with manufacturer programming instructions
  • 2.4Entered data is checked as meeting those specified by work activity and job specifications
  • 2.5Unplanned situations are responded to in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
  • 2.6Programming is carried out efficiently without waste of materials and energy or damage to apparatus, the surrounding environment or other services

3 Test fire protection device operation and report findings

  • 3.1Fire protection device operation is tested in accordance with WHS/OHS requirements and workplace procedures
  • 3.2Operating anomalies are identified and corrected in accordance with workplace procedure
  • 3.3WHS/OHS work completion risk control measures and workplace procedures are followed
  • 3.4Worksite is cleaned and made safe in accordance with workplace procedures
  • 3.5Work completion is reported and appropriate person/s notified in accordance with workplace procedure

Performance evidence

  • apply sustainable energy principles and practices
  • applying relevant work health and safety (WHS)/occupational health and safety (WHS/OHS) requirements, including using risk control measures
  • correcting programming anomalies
  • dealing with unplanned events/situations in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
  • entering functions and parameters correctly
  • identifying non-compliance conditions of device installation
  • performing program backups, version controls and documentation
  • testing and verifying device operation
  • understanding required operating functions and parameters

Knowledge evidence

  • fire protection systems programming methods
  • input devices, including conventional alarm zones, analogue or analogue addressable fire detectors, flow switch connections or switch connections
  • logic times, including software programs that control the operation of non-latching detectors and timer periods before operation of fire system suppression systems
  • output devices, including shutdown signal, door or system release controls and solenoid valve controls
  • program backup, version control and documentation requirements
  • program loading methods and relevant information technology
  • program testing methods
  • relevant manufacturer specifications
  • relevant job safety assessments or risk mitigation processes
  • relevant WHS/OHS legislated requirements
  • relevant workplace documentation
  • relevant workplace policies and procedures
  • system interface controls, including verify signals to remote control and indicating equipment, building monitoring systems, paging system and colour graphics
  • system variables, including standard software functions that operate smoke detector controls, dual zone alarm configurations, alarm and fault global functions
  • vender programming codes and functions, including: input/output (I/O) instructions variables timers limitations of vender software

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing UEEEC0026

What does an assessment tool for UEEEC0026 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for UEEEC0026 needs to address all 41 unit components: 3 elements with 17 performance criteria, 9 performance evidence requirements, 15 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for UEEEC0026?

Auditori pulls the current release of UEEEC0026 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for UEEEC0026 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing UEEEC0026 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of UEEEC0026, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your UEEEC0026 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate UEEEC0026 free