TLILIC0005 — Licence to operate a boom-type elevating work platform (boom length 11 metres or more)
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for TLILIC0005 must cover
87 assessable components: 4 elements (36 performance criteria), 24 performance evidence and 27 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Plan work/task
- 1.1Task requirements are identified from work orders or equivalent and confirmed with relevant people and a site inspection is completed in accordance with workplace procedures
- 1.2Work area ground/operating surface is assessed to determine suitability for operational use of EWP in accordance with manufacturer requirements and workplace procedures
- 1.3EWP capabilities are established for the load/s and work/task requirements in accordance with manufacturer requirements and workplace procedures
- 1.4Appropriate paths for operating the EWP and moving in work area are assessed and determined in accordance with workplace procedures
- 1.5Relevant hazard and risk control measures are applied and advised to relevant person/s in accordance with workplace procedures
- 1.6Traffic management plan implementation is confirmed in accordance with workplace procedures
- 1.7Appropriate communication procedures are identified, with relevant people in accordance with workplace procedures
- 1.8All work is confirmed to ensure coverage of work/task requirements for the relevant work area in accordance with workplace procedures
2 Prepare for work/task
- 2.1Consultation with workplace person/s is maintained to ensure workplan is clear and consistent with site requirements in accordance with workplace procedures
- 2.2Risk control measures for hazards identified are checked for implementation in accordance with workplace procedures
- 2.3Safety equipment including Personal Protective Equipment (PPE) are inspected, fitted correctly and used in accordance with manufacturer requirements and safe work procedures
- 2.4EWP is accessed in a safe manner in accordance with manufacturer requirements and safe work procedures
- 2.5Pre-start EWP checks are carried out in accordance with manufacturers requirements and safe work procedures
- 2.6EWP is started and is checked for any abnormal noises in accordance safe work procedures
- 2.7EWP is positioned correctly as per work plan in work area in accordance with relevant manufacturer requirements and safe work procedures
- 2.8EWP is stabilised appropriately in accordance with the workplan, relevant manufacturer requirements and safe work procedures
- 2.9Operational checks from base controls are carried out in accordance with relevant manufacturer requirements and safe work procedures
- 2.10All platform controls are located, identified and tested in accordance with manufacturer requirements and safe work procedures
- 2.11All damage and defects are reported and appropriate action is taken to rectify in accordance with manufacturer requirements and safe work procedures
- 2.12EWP logbook is inspected and is correct for the EWP, is completed and signed in accordance with manufacturer requirements and safe work procedures
- 2.13Weather and work environmental conditions are assessed to determine any impact on EWP operation and positioning as per workplan in accordance with manufacturer requirements and safe work procedures
3 Perform work/task
- 3.1Relevant hazard prevention/control measures identified are checked for implementation in accordance with safe work procedures
- 3.2EWP is safely located at point of work in work area in accordance with safe work procedures
- 3.3EWP platform is positioned for work tasks and stability and all operations are monitored constantly in accordance with safe work procedures
- 3.4Work gear and tools are stowed and secured in accordance with safe work procedures
- 3.5EWP is operated using all movements in accordance with safe work procedures and manufacturer requirements
- 3.6Unplanned and unsafe situations are responded to in accordance with safe work procedures
- 3.7All communication signals are correctly interpreted and followed whilst EWP is operated in accordance with safe work procedures
- 3.8EWP platform is accessed and egressed in accordance with safe work procedures and manufacturer requirements
- 3.9EWP is parked, switched off and isolated appropriately in accordance with manufacturer requirements and safe work procedures
4 Pack up
- 4.1Post-operational EWP checks are carried out in accordance with manufacturer requirements and safe work procedures
- 4.2EWP boom is retracted, lowered, stowed and secured in accordance with manufacturer requirements and safe work procedures
- 4.3Safety equipment and PPE is disconnected from platform in accordance with safe work procedures
- 4.4Relevant motion locks and brakes are applied as required in accordance with manufacturer requirements and safe work procedures
- 4.5Outriggers and/or stabilisers, plates or packing if fitted are stowed and secured in accordance and with manufacturer requirements and safe work procedures
- 4.6EWP is shut down in accordance with manufacturer requirements and safe work procedures
Performance evidence
- advising relevant person/s on site in relation to any hazards and risk elimination/control strategies
- applying safe operating procedures for an Elevating Work Platform (EWP) including all functions within the safe working rated capacity including: boom/s as low as possible and fully retracted whilst travelling (self propelled EWP only), boom/s in line with EWP where practical whilst travelling (self propelled EWP only), EWP stability, gently accelerating and braking to minimise boom/s swing (self propelled EWP only), maintaining safe operating speed in relation to the work condition, travelling with work platform raised to an appropriate height for the terrain and visibility in relation to direction of travel (self propelled EWP only and in accordance with manufacturers specifications)
- applying emergency procedures
- applying traffic management plan procedures relevant to their role in the work area
- carrying out operational checks on EWP including: testing of all EWP safety devices, all controls are located, identified and tested for functionality from the base controls and platform controls, hazard warning systems including travel beepers and lights are functional, start-up is in accordance with manufacturer requirements, steering, transmission and brake functions comply with operating requirements (self propelled EWP only), there are no unusual noises
- carrying out pre-start checks, including visual inspection which must include: battery fluid level as required by manufacturer requirements, checking compliance plate is relevant to the load/s being used on the EWP, engine / mechanical fluid level checks as required by manufacturer requirements, ensuring availability of correct logbook and updating records as required, ensuring EWP platform and attachment/s fitted in platform are secured, evidence of damage, fluid leaks, lights are working effectively (where fitted), safety equipment checks, signage and labels to ensure they are visible and legible, structural weaknesses including paint separation or stressed welds, wheels and tyres for damage/correct inflation if applicable
- checking compliance plate and load chart for reach requirements and load suitability
- clarifying workplan and checking understanding
- complying with Commonwealth, State and/or Territory work health and safety (WHS)/occupational health and safety (OHS)/occupational safety and health (OSH) legislation and regulations
- controlling and operating a boom type elevating work platform ensuring movements and control functions are safe, smooth and comply with operating requirements including: any combination of the movement of the extending boom used to support a platform on which personnel, equipment and materials are elevated to perform the work task/s, avoidance of ground depressions, correctly using observer guidance of work platform, main chassis and extending boom, demonstrating the safe operation of an EWP in forward and reverse, while maintaining visibility (where applicable), driving (where applicable) applicable to conditions and moving platform and load/s safely, ensuring warning devices are functioning correctly, interpreting directional arrows correctly on platform controls during forward, reverse, left and right, lowering boom to its resting position, monitoring platform, main chassis and extending boom movement constantly ensuring safe work procedures are followed, raising platform and slewing within manufacturer requirements, raising platform to its full extent or 75% of the maximum height capacity (whichever is greater), stability of the EWP and the work platform
- manoeuvring and positioning the platform to perform work task/s safely whilst at its full extent or a minimum height of 75% of the maximum capacity (whichever is greater)
- conducting and applying hazard identification and risk elimination or minimisation strategies including: barricades and controls to prevent the risk of collision with people, moving vehicles and fixed structures, environmental conditions including: wind, lightning, water impacted ground, rain, extreme heat, Ultra Violet (UV) exposure, ground conditions (surface and slopes) and assessing work area operating surface suitability based on machine and task requirements, overhead hazards including electric lines and service pipes, personal protective equipment (PPE), restricted areas and crush points from work platform and external surroundings, safety related tags on electrical switches/isolators that have an impact on point of work of EWP operator, sufficient lighting, suitable area for set-up, positioning and safely operating EWP, suitable firm and stable operating surface, use of safety observer
- entering work platform correctly including: lowering platform safely and stably to appropriate height to access safely, clipping on of fall restraint/arrest device, accessing platform safely
- exiting work platform correctly including: lowering platform safely and stably to appropriate height to egress safely, unclipping of fall restraint/arrest device, exiting platform safely
- identifying, isolating and tagging out defective equipment and reporting to authorised person/s
- inspecting and using relevant safety equipment, including: anchor point/s, emergency retrieval system from base controls and platform controls where fitted, energy absorber/s, lanyard/s, safety harness/es
- interpreting and confirming relevant documentation, workplace instructions, safety information and emergency procedures for the work task and relevant area
- interpreting workplace procedures in relation to various work environmental conditions
- maintaining communication with other workplace personnel using appropriate workplace procedures including procedures to ensure all movements are conveyed clearly and succinctly including: 2-way radio, audible and visual warning devices, making and interpreting hand signals, questioning to confirm understanding, signage, written instructions
- recording and maintaining accurate information relating to EWP operations
- reporting to relevant person/s on site risk control measures that are not in place or deficient
- stabilising procedures for an EWP including: checking levels, removing obstacles and obstructions, deploying and retracting outriggers (if fitted), establishing correct size plates for packing (if required)
- shutting down a boom type EWP in accordance with manufacturer requirements and workplace procedures
- using and interpreting EWP manufacturer requirements and data, including compliance plate and load chart, to enable correct EWP selection for task including: boom, platform, weight including outrigger load or wheel load.
Knowledge evidence
- Australian and industry standards, codes of practice and guidelines to safely operate an EWP (boom length 11 metres or more) including: nominal reach, measured horizontally from centre point of rotation to outer edge of platform in its most extended position, vertical distance from floor of platform to surface supporting elevating work platform with platform at its maximum height
- appropriate mathematical calculations to estimate loads ensuring EWP is not overloaded
- appropriate workplace communication procedures including: 2-way radio, audible and visual warning devices, questioning techniques, signage, hand signals, traffic warning systems, written instructions
- compliance with permit condition requirements including: from electrical supply authority, if operating on roads or footpaths
- EWP characteristics and capabilities, manufacturer requirements and instructions
- hazards including: all ground and /or operating surface hazards, traffic including pedestrians, vehicles, other mobile plant and building structures, overhead hazards including electric lines, service pipes, doorways, roof beams, and lights, obstacles or obstructions, insufficient lighting, other relevant hazards
- identification and avoidance of person/s potential crush or entrapment points
- identification and avoidance of potential contact with overhead electrical conductor’s
- identification and avoidance of potential contact with structures near work platform/boom or chassis
- impact of the following on the operation of the EWP including: failure/loss of control including brakes and steering, failure of equipment including hydraulic system, EWP and platform instability due to: deterioration of ground/operating surface condition, gradient of operating surface, overloading, poor load placement, irregular loads
- emergency procedures and safety equipment, including the use of: safety harness/es, energy absorbers, lanyard/s, anchor point/s, emergency retrieval systems
- lock out and tag out procedures
- problems, and appropriate response procedures to unplanned and/or unsafe environmental conditions
- procedures for recording, reporting and maintaining workplace records and information
- relevant manufacturer requirements and instructions
- relevant procedures for refuelling/recharging EWP using appropriate PPE
- risk assessment process including hierarchy of control: elimination, substitution, isolation, engineering controls, administrative controls, personal protective equipment (PPE)
- problems and equipment faults, and implementing appropriate response procedures to unplanned and/or unsafe situations
- procedures for shutting down a boom type EWP in accordance with manufacturer requirements
- relevant documentation requirements
- suitability and lifting capability of the EWP to be used
- traffic management plan procedures and requirements
- typical routine problems encountered operating a EWP and adjustments required for correction
- wind speed factors that affect stability of EWP as per manufacturer requirements
- work area operating surface suitability including issues with: backfilled ground, bitumen (damaged, cracked), concrete (damaged, cracked), hard compacted soil, potholes, railway tracks, rough uneven or difficult terrain including sloping surfaces, uneven surfaces, steel decks and grates, soft soils, trench covers
- work health and safety (WHS)/occupational health and safety (OHS)/occupational safety and health (OSH) and codes of practice requirements for boom type elevating work platforms
- work plan which may be verbal, documented/written, or electronically generated
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing TLILIC0005
What does an assessment tool for TLILIC0005 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for TLILIC0005 needs to address all 87 unit components: 4 elements with 36 performance criteria, 24 performance evidence requirements, 27 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for TLILIC0005?
Auditori pulls the current release of TLILIC0005 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for TLILIC0005 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing TLILIC0005 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of TLILIC0005, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- TLILIC0001 — Licence to transport dangerous goods by road
- TLILIC0003 — Licence to operate a forklift truck
- TLILIC0004 — Licence to operate an order picking forklift truck
- TLILIC0011 — Licence to operate a reach stacker (greater than 3 tonnes capacity)
- TLILIC0016 — Licence to operate a bridge and gantry crane
- TLILIC0017 — Licence to operate a derrick crane
- TLILIC0019 — Licence to operate a portal boom crane
- TLILIC0020 — Licence to operate a slewing mobile crane (over 100 Tonnes)
- TLILIC0021 — Licence to operate a slewing mobile crane (up to 100 Tonnes)
- TLILIC0022 — Licence to operate a slewing mobile crane (up to 20 tonnes)
- TLILIC0023 — Licence to operate a slewing mobile crane (up to 60 tonnes)
- TLILIC0024 — Licence to operate a vehicle loading crane (capacity 10 metre tonnes and above)
Your TLILIC0005 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate TLILIC0005 free