SHBBHRS005 — Identify and control safety risks for intense pulsed light and laser hair reduction treatments
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for SHBBHRS005 must cover
47 assessable components: 4 elements (21 performance criteria), 4 performance evidence and 20 knowledge evidence requirements, plus 2 foundation skills. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Identify health and safety requirements for intense pulsed light and laser hair reduction treatments.
- 1.1Interpret workplace policies and procedures to identify workplace health and safety requirements for provision of intense pulsed light and laser hair reduction treatments.
- 1.2Interpret legislative, regulatory, compliance and licencing information to identify regulatory health and safety requirements for the provision of intense pulsed light and laser hair reduction treatments.
- 1.3Interpret industry and safety standard information to identify industry and standard health and safety requirements for the provision of intense pulsed light and laser hair reduction treatments.
- 1.4Identify safety hazards related to features and functions of equipment used in intense pulsed light and laser hair reduction treatments.
2 Assess and control safety risks in the treatment environment.
- 2.1Complete equipment maintenance checks as per organisational requirements and manufacturer instructions.
- 2.2Comply with manufacturer instructions, safety data sheets and workplace policies and procedures to ensure correct functioning of intense pulsed light and laser equipment.
- 2.3Review logs to confirm routine maintenance of intense pulsed light and laser equipment has occurred.
- 2.4Troubleshoot, report and escalate equipment and treatment safety issues according to workplace policies and procedures.
- 2.5Report and document equipment failures and faults to relevant personnel.
- 2.6Check window coverings, hazard and warning signs to ensure they are correctly installed and used according to workplace policies and procedures and legislative requirements.
- 2.7Check treatment environment to ensure it is fitted with required plume extractor and smoke evacuation systems that provide safe ventilation according to current standards and workplace policies and procedures.
- 2.8Identify and remove potentially flammable and combustible items from treatment area.
- 2.9Check to ensure suitable fire extinguishers are available and correctly maintained.
- 2.10Prepare treatment area to minimise risk of laser treatment fire hazard associated with reflective equipment
- 2.11Complete clinical procedure checklists and records according to federal, state or territory and local legislation, regulations and workplace policies and procedures.
- 2.12Clean, sanitise and store equipment according to manufacturer instructions and workplace policies and procedures.
3 Assess and control safety risks to practitioner and client.
- 3.1Identify actual and potential safety hazards and assess risks that may pose harm to the health and safety of practitioner, client and others who may be present during treatment.
- 3.2Use correct personal protective equipment for practitioner, client and others who may be present during treatment.
4 Respond to health and safety risks.
- 4.1Complete on-the-spot risk assessment and determine action and control measures to avoid injury to practitioner, client and others who may be present during treatment.
- 4.2Take action to control safety risks within scope of own responsibility or refer to appropriate personnel for action.
- 4.3Complete reporting and documentation according to workplace policies and procedures.
Performance evidence
- identify three safety hazards and complete three risk assessments in at least one of the following: - an intense pulsed light treatment environment - a laser treatment environment
- develop, implement and maintain safety practices and risk control measures to respond to safety hazards associated with use of at least one of the following: - intense pulsed light - laser
- for the above, record the following: - workplace documentation and checks for the maintenance of equipment - workplace health and safety reporting related to intense pulsed light or laser hair reduction treatments
- during risk assessments, follow workplace policies and procedures, non-ionising radiation safety protection plan and relevant state or territory laws, codes and guidelines related to the use of intense pulsed light and laser for hair reduction.
Knowledge evidence
- key aspects of current legislation, regulation and industry standards and guidelines relevant to intense pulsed light and laser hair reduction treatments: - laser classification and hazard analysis - maintenance and auditing of facilities - equipment inspection and maintenance protocols - investigation and management of intense pulsed light and laser incidents - personal protective equipment - potential for fire and explosion and protection against flammability hazards - management of airborne contaminants
- electrical safety laser controlled treatment areas: - designation - warning signs - entry controls - control of access to the laser
- safety of intense pulsed light and laser products - equipment classification - safe use of intense pulsed light and laser equipment
- intense pulsed light and laser hazards: - beam hazards - non-beam hazards
- risk and hazard management including risk assessment
- hierarchy of hazard control: - engineering controls - administration controls - personal protective equipment
- quality assurance testing and preventive maintenance
- safe work practices
- workplace work health and safety policies: - procedures for: - identifying hazards - assessing risk - controlling risk - non-ionising radiation safety protection plan - ergonomics
- types of safety hazards related to intense pulsed light and laser hair reduction and associated control measures: - ocular and skin - equipment specific - reflected beams - fire, explosive, electrical and environmental
- control measures applied to minimise health and safety risks during intense pulsed and laser hair reduction treatments: - pre-treatment patch testing - personal protective equipment: - eye protection - masks - gowns - gloves - ventilation systems - filtering and exhaust systems - window coverings - draping of treatment environment
- equipment preventive maintenance: - documentation, including: - equipment safety standards - equipment service history - schedule for recommended testing and maintenance - regular testing
- biophysics of laser and intense pulsed light technologies as outlined in AS/NZS 4173:2018, Safe use of lasers and intense light sources in health care or its replacement
- how light energy interacts with skin and hair
- physics of light related to intense pulsed light and laser treatments: - energy forms - electromagnetic spectrum - optical region of the electromagnetic spectrum - wavelengths - characteristics of a wave
- operational characteristics of lasers: - programmable systems - basic set-up (manual choice) - generation of laser beam and propagation of light - characteristics of laser beams - properties of different types of lasers - optical pathways - delivery systems and applicators used for hair reduction
- operational characteristics of intense pulsed light apparatus: - programmable systems - basic set-up (manual choice) - powerful systems - significantly lower power systems - common differences in imported systems - chilled sapphire or similar optical substance head - non-chilled sapphire head - non-laser light source - characteristics of flashlamp - capacitors - free discharge and partial discharge - different filters - properties of intense pulsed light equipment
- laser controls: - emergency control - delivery systems - ionising and non-ionising radiation
- parameters that effect the delivery of light: - spectrum of delivered wavelengths as determined by cut-off filters - number of delivered pulses, including single and multiple pulsed shots - pulse duration in milliseconds - delay between pulses in milliseconds - delivered fluence
- laser hazards.
Foundation skills
- Reading skills: to: - interpret both familiar and unfamiliar, and sometimes complex documents: - workplace policies and procedures - materials describing industry and regulatory requirements of intense pulsed light and laser hair reduction - non-ionising radiation safety protection plan - manufacturer instructions for the safe use, maintenance and storage of intense pulsed light and laser equipment.
- Numeracy skills: to: - comprehend units of measurement related to laser and intense pulsed light apparatus.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing SHBBHRS005
What does an assessment tool for SHBBHRS005 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for SHBBHRS005 needs to address all 47 unit components: 4 elements with 21 performance criteria, 4 performance evidence requirements, 20 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for SHBBHRS005?
Auditori pulls the current release of SHBBHRS005 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for SHBBHRS005 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing SHBBHRS005 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of SHBBHRS005, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- SHBBHRS006 — Design laser hair reduction treatment programs
- SHBBHRS007 — Provide laser hair reduction treatments
- SHBBHRS008 — Design intense pulsed light hair reduction treatment programs
- SHBBHRS009 — Provide intense pulsed light hair reduction treatments
- SHBBHRS010 — Provide waxing services
- SHBBHRS011 — Provide female intimate waxing services
- SHBBHRS012 — Provide male intimate waxing services
- SHBBHRS013 — Provide hair reduction treatments using electrical currents
Your SHBBHRS005 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate SHBBHRS005 free