RIIPRE301DConduct electrowinning/electro-refining operations

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for RIIPRE301D must cover

45 assessable components: 5 elements (38 performance criteria), 3 performance evidence and 4 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Plan and prepare for electrowinning/ electro-refining

  • 1.1Access, interpret and apply c documentation and procedures for conducting electrowinning electro-refining operations and ensure the work activity is compliant
  • 1.2Receive, interpret and clarify shift changeover details
  • 1.3Communicate job requirements with other personnel
  • 1.4Select personal protective equipment appropriate for work activities
  • 1.5Select appropriate type of auxiliary equipment for work activities
  • 1.6Perform equipment pre-start checks
  • 1.7Identify, address and report potential risks and hazards
  • 1.8Identify, address and report environmental issues
  • 1.9Adhere to emergency procedures
  • 1.10Use dust suppression and extraction methods
  • 1.11Ensure area is well ventilated

2 Monitor electrowinning/ electro-refining

  • 2.1Monitor, gather and interpret data from equipment indicators
  • 2.2Monitor and adjust solution volume, feed quality and rate of flow in cells
  • 2.3Monitor cooling system according to site procedures
  • 2.4Monitor and maintain temperature, voltage and amps.
  • 2.5Continuously monitor operations
  • 2.6Minimise and monitor emissions
  • 2.7Complete all required documentation
  • 2.8Pass on end of shift information to oncoming shift
  • 2.9Conduct cell inspections
  • 2.10Observe and follow electrical safety techniques

3 Pull and strip plates

  • 3.1Ensure that electrowinning/electro-refining systems are safe for plate removal
  • 3.2Pull and strip plates using appropriate equipment
  • 3.3Inspect electrodes and identify rejects
  • 3.4Strip plates to site requirements
  • 3.5Stack and dispatch stripping products
  • 3.6Clean plates for reuse
  • 3.7Handle stripping products safely

4 Shutdown in sequence and/or isolate equipment

  • 4.1Shutdown or isolate equipment based on process and safety requirements
  • 4.2Perform post shutdown or isolation checks
  • 4.3Plan for shutdown/isolation and returning cells to service

5 Conduct housekeeping activities and return cell to service

  • 5.1Clean plant and maintain condition of equipment, ensure suitability for use and address/report issues
  • 5.2Manage and/or report hazards, and maintain a safe working environment
  • 5.3Maintain bus-bar cleanliness
  • 5.4Isolate cell and remove scale from anodes and cell according to site requirements
  • 5.5Dispose of scale in accordance with site procedures
  • 5.6Return cell to service in correct sequence
  • 5.7Process records

Performance evidence

  • locates and applies relevant documentation, policies and procedures
  • implements the requirements, procedures and techniques for the safe, effective and efficient completion of electrowinning/electro-refining operations including: identifying and applying required environmental controls; identifying and managing hazards affecting the sinter of materials; identifying and applying dust suppression and extraction methods; handling hazardous substances correctly; identifying and applying isolation procedures
  • demonstrates completion of electrowinning/electro-refining operations that safely, effectively and efficiently meets all of the required outcomes on more than one (1) occasion including: performing start up in sequence on equipment to meet job requirements; operating plant to meet job requirements; reading equipment indicators; adjusting equipment to maintain optimum output; pulling and stripping plates; shutting down and/or isolating the equipment in sequence; performing routines checks on equipment

Knowledge evidence

  • equipment operating parameters and safety requirements
  • operational procedures and checks, including equipment inspection and rejection/replacement requirements
  • metallurgical and technical data
  • pumping system and flow charts (pipeline and sprinkler systems)

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing RIIPRE301D

What does an assessment tool for RIIPRE301D need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for RIIPRE301D needs to address all 45 unit components: 5 elements with 38 performance criteria, 3 performance evidence requirements, 4 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for RIIPRE301D?

Auditori pulls the current release of RIIPRE301D from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for RIIPRE301D — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing RIIPRE301D assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of RIIPRE301D, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your RIIPRE301D assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate RIIPRE301D free