PMAOPS226 — Monitor and operate flare systems
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for PMAOPS226 must cover
37 assessable components: 4 elements (25 performance criteria), 4 performance evidence and 8 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Monitor flare system
- 1.1Identify and control flare system hazards
- 1.2Visually inspect the flare and flare system components for compliance to requirements
- 1.3Take relevant readings
- 1.4Check for process causes of identified problems
- 1.5Check for other causes of identified problems
- 1.6Take actions specified in the procedures
- 1.7Complete logs as required
2 Shut down flare system
- 2.1Obtain required authorisations for a flare shutdown
- 2.2Notify other relevant plants/units of planned shutdown
- 2.3Identify and control flare shutdown hazards
- 2.4Purge and isolate flare system
- 2.5Complete other preparations for flare shutdown according to procedures
- 2.6Shut down according to procedures
3 Start up flare system
- 3.1Check all required work has been completed
- 3.2Check integrity of components
- 3.3Notify other relevant plants/units of planned start-up
- 3.4Identify and control flare start-up hazards
- 3.5De-isolate and purge flare system
- 3.6Complete other preparations for flare start-up according to procedures
- 3.7Start up flare system according to procedures
4 Solve flare system problems
- 4.1Recognise and respond to abnormal conditions
- 4.2Identify other problems in flare system
- 4.3Take action to remedy flare problems in accordance with procedures
- 4.4Communicate relevant information
- 4.5Complete required documentation
Performance evidence
- monitor and inspect flare systems
- shut down/start up flare systems according to procedures
- recognise conditions which indicate a problem and take appropriate action
- convey information relevant to the operation clearly and effectively.
Knowledge evidence
- hazards that may arise in the job/work environment, and: their possible causes, potential consequences, appropriate risk controls
- flare system operating principles, requirements and parameters
- routine problems, faults and their symptoms and the corrective action to be taken
- knock on/escalation potential
- process materials likely to be flared and the conditions which will lead to flaring
- relevant environmental requirements
- significance of the exclusion zone
- flare start-up, re-ignition and shutdown procedures.
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing PMAOPS226
What does an assessment tool for PMAOPS226 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for PMAOPS226 needs to address all 37 unit components: 4 elements with 25 performance criteria, 4 performance evidence requirements, 8 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for PMAOPS226?
Auditori pulls the current release of PMAOPS226 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for PMAOPS226 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing PMAOPS226 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of PMAOPS226, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- PMAOPS101 — Read dials and indicators
- PMAOPS105 — Select and prepare materials
- PMAOPS201 — Operate fluid flow equipment
- PMAOPS202 — Operate fluid mixing equipment
- PMAOPS204 — Select and use utilities and services
- PMAOPS205 — Operate heat exchangers
- PMAOPS208 — Operate chemical separation equipment
- PMAOPS210 — Operate solids handling equipment
- PMAOPS213 — Package product/material
- PMAOPS216 — Operate local control system
- PMAOPS217 — Operate wet milling equipment
- PMAOPS220 — Monitor chemical reactions in the process
Your PMAOPS226 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate PMAOPS226 free