MSL975060 — Perform tissue or cell culture techniques
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for MSL975060 must cover
56 assessable components: 7 elements (32 performance criteria), 2 performance evidence and 22 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Interpret and schedule production requirements
- 1.1Review client request and confirm quantity and nature of cells or tissue
- 1.2Select appropriate media, materials, equipment and methods
- 1.3Plan parallel work sequences to optimise production
- 1.4Maintain a chain of custody, traceable to the worker, for all cells or tissues
2 Work safely according to the legal and regulatory framework
- 2.1Identify hazards and workplace control measures associated with the sample, preparation methods, reagents and equipment
- 2.2Select, fit and use personal protective equipment (PPE)
- 2.3Address hazards and incidents as they arise in accordance with workplace procedures
- 2.4Safely dispose of biohazardous materials and other laboratory waste
3 Assemble and maintain tissue culture equipment
- 3.1Assemble, sterilise or decontaminate equipment according to workplace procedures
- 3.2Perform pre-use and safety checks in accordance with relevant workplace and operating procedures
- 3.3Identify faulty or unsafe components and equipment and report to appropriate personnel
- 3.4Decontaminate area and equipment after use
4 Prepare and test cell or tissue culture media
- 4.1Confirm media specifications and processes/methods
- 4.2Prepare culture media to suit client request
- 4.3Sterilise culture media and check for sterility
- 4.4Perform quality control checks to ensure that culture media is fit for purpose
- 4.5Store culture media in accordance with specifications
5 Obtain, monitor and maintain tissue or cell lines
- 5.1Access the cell lines or tissue sample from fresh or preserved sources and prepare a culture
- 5.2Select specified culture media and add any necessary growth agents or nutrients
- 5.3Incubate cells or tissue in specified conditions
- 5.4Inoculate the media with the specified amount of sample
- 5.5Monitor growth of tissue or cell lines and products
- 5.6Detect contamination/abnormalities and troubleshoot materials, equipment and techniques
- 5.7Passage samples by subculturing to preserve or grow the line
- 5.8Harvest tissue, cells or cell products to optimise yields
6 Preserve cells or tissues
- 6.1Select the appropriate preservation method
- 6.2Preserve the cell lines or tissue in accordance with the method
- 6.3Check preserved tissue or cell lines regularly to ensure viability is maintained
7 Maintain records
- 7.1Maintain accurate records of batches of media
- 7.2Maintain accurate records of active and stored tissue or cell lines
- 7.3Complete records so that they are retrievable, legible and accurate
- 7.4Ensure records conform to the information management, records, quality system and legal requirements
Performance evidence
- safely prepared and maintained 3 different cell and/or tissue cultures to preserve cells and cell lines that are fit for purpose without contaminating the original sample, including: subculturing cell or tissue cultures, preserving cell lines or tissue by freezing, confirming the identity of the cell lines or tissue and identifying abnormalities/contamination if present
- maintained accurate, traceable records of cell lines or tissue and logs of procedures and work completed
Knowledge evidence
- terminology, including cell lines, growth media, primary culture, passaging, passage number, subculture, anchorage dependent cells, suspension culture, monolayer, confluent, cell line, cell strain, contact inhibition, diploid and viability
- cell biology, including structure, physiology, function, physiological cell growth requirements, nutrient requirements, respiration, temperature and growth cycle
- general purpose of cell lines
- normal and abnormal cell morphology
- critical components of the cell environment and their effects on cell growth, including pH, temperature, buffering, atmosphere, osmotic pressure, osmolarity and viscosity
- types of tissue and cells used as source material
- techniques for characterising a cell line
- selection criteria for media, materials and equipment, including: costs, ease of cleaning or sterilisation, maintenance of cell growth
- the differences between finite and continuous cell lines
- characteristics of cell culture media and substrates
- nature of substrates including solid, semi-solid, gel or sponge, glass, disposable plastics and three-dimensional matrices
- cell and tissue preservation methods
- chemical treatment techniques for pre-treating substrates relevant to the job role
- role of common ingredients in media including salts, carbohydrates, amino acids, vitamins, growth factors, serum and antimicrobial
- contaminants, including endotoxins, bacteria, yeast, fungi and mycoplasma
- typical requirements, problems and procedures associated with the production of specific cell lines relevant to the job role
- tissue culture and continuous culture systems
- methods to prepare primary cultures
- principles and purpose of techniques implemented
- methods to monitor growth of tissue and cell lines
- environmental sustainability issues as they relate to the work task
- legal, ethical and work health and safety (WHS) requirements specific to the work task including traceability, confidentiality and security requirements of all client information, and laboratory data and records
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing MSL975060
What does an assessment tool for MSL975060 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for MSL975060 needs to address all 56 unit components: 7 elements with 32 performance criteria, 2 performance evidence requirements, 22 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for MSL975060?
Auditori pulls the current release of MSL975060 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for MSL975060 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing MSL975060 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of MSL975060, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- MSL904003 — Perform standard calibrations
- MSL905004 — Perform non-standard calibrations
- MSL905005 — Create or modify calibration procedures
- MSL912002 — Work within a laboratory or field workplace
- MSL913004 — Plan and conduct laboratory/field work
- MSL914002 — Prepare practical science classes and demonstrations
- MSL915003 — Provide information to customers
- MSL915004 — Schedule laboratory work for a small team
- MSL916011 — Develop and maintain laboratory documentation
- MSL916012 — Manage and develop teams
- MSL916013 — Supervise laboratory operations in work or functional area
- MSL916014 — Maintain compliance in work or functional area
Your MSL975060 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate MSL975060 free