MARB047Undertake maintenance of 240 to 440 voltage alternating current electrical systems

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for MARB047 must cover

70 assessable components: 7 elements (46 performance criteria), 12 performance evidence and 12 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Verify maintenance requirements

  • 1.1Regulatory and organisational requirements for electrical system maintenance program are identified and followed
  • 1.2Specifications, diagrams and organisational procedures for electrical systems are checked for recommended maintenance
  • 1.3Special requirements for electrical system maintenance are separated from adjustment and day-to-day maintenance schedules
  • 1.4Maintenance system goals for electrical systems are outlined
  • 1.5Maintenance plan and related work schedule for electrical systems are developed according to regulatory requirements and safety management system (SMS)

2 Establish maintenance systems

  • 2.1Maintenance costs are identified and quantified
  • 2.2Interruptions, processes and procedures are documented
  • 2.3Internal and external maintenance providers are specified
  • 2.4Maintenance plan is prepared to minimise negative impacts on production, costs, waste and the environment
  • 2.5Approvals for maintenance plan are negotiated and confirmed
  • 2.6Recordkeeping systems are developed and maintained

3 Organise maintenance activities

  • 3.1Schedules and rosters are checked to verify time when maintenance process may be scheduled, including optimal timing for shutdown
  • 3.2Agreement from Master is obtained for timing of maintenance tasks to optimise maintenance process and minimise operational disruptions
  • 3.3Detailed work plans are developed in line with schedules, availability of expertise and scheduling of resource availability
  • 3.4Team members with required competencies are allocated to maintenance activities
  • 3.5Consumables and equipment are secured to meet work plan requirements
  • 3.6Externally sourced equipment, consumables and expertise are located and procured
  • 3.7Contingency plans are prepared
  • 3.8Maintenance schedules and procedures are effectively communicated to team

4 Supervise maintenance tasks

  • 4.1Job specifications and maintenance tasks are communicated effectively to team members
  • 4.2Maintenance and repair tasks are monitored to ensure they satisfy system specifications
  • 4.3Work health and safety (WHS)/occupational health and safety (OHS)) requirements are monitored and observed at all times
  • 4.4Emergency equipment is made available and working order of equipment is ensured
  • 4.5Contingencies are managed to ensure quality of work is maintained and work is completed within agreed timeframe

5 Perform planned maintenance activities

  • 5.1WHS/OHS risk control measures and procedures for carrying out work are followed
  • 5.2Maintenance schedule and process compliance requirements are confirmed and work is appropriately sequenced according to job specification
  • 5.3Appropriate person/s is consulted to ensure work is coordinated effectively with others
  • 5.4Resources needed to conduct maintenance are obtained according to organisational procedures and are checked against job requirements
  • 5.5Tools, equipment and testing devices needed to conduct maintenance are obtained according to organisational procedures and checked for correct operation and safety
  • 5.6Live and operating system is tested or measured strictly according to WHS/OHS requirements and within established safety procedures
  • 5.7Electrical equipment is checked as being isolated, where necessary, strictly according to WHS/OHS requirements and within established safety procedures
  • 5.8Electrical equipment to be maintained is inspected and evaluated for compliance with system specifications
  • 5.9Non-compliant electrical equipment components are rectified or repaired according to system specifications

6 Perform breakdown maintenance

  • 6.1Nature of breakdown is confirmed with appropriate personnel
  • 6.2Extent of breakdown is evaluated and confirmed using diagnostic and troubleshooting techniques
  • 6.3Restrictions are applied to operations, as necessary, and agreed to with the Master
  • 6.4Electrical equipment is checked as being isolated, where necessary, strictly according to WHS/OHS requirements and within established safety procedures
  • 6.5Repair work is carried out according to system specifications
  • 6.6Master is notified of completion of repair work and details are documented

7 Monitor, adjust and report on implementation of maintenance plan

  • 7.1Maintenance tasks are monitored to ensure they are completed according to maintenance plan and statutory survey requirements
  • 7.2Electrical systems are monitored to ensure achievement of planned outcomes
  • 7.3Costs are monitored and controlled
  • 7.4Adjustments are made to maintenance plan to take into account failure to achieve planned outcomes
  • 7.5Reports are completed according to maintenance plan requirements and organisational procedures
  • 7.6Recommendations to improve maintenance plan safety, efficiency and effectiveness are implemented under regular review of SMS
  • 7.7Maintenance tasks are monitored to ensure they are completed according to maintenance plan and statutory survey requirements

Performance evidence

  • applying safety requirements throughout work sequence, including the use of personal protective equipment (PPE)
  • completing all work to specification
  • completing records, including: incident reports, maintenance logs, reports required under planned maintenance system
  • developing effective planning documents
  • ensuring correct requirements and details of maintenance of electrical systems and equipment
  • implementing safe and environmentally responsible work practices in testing and maintenance activities
  • locating, interpreting and applying manufacturer specifications for electrical systems and equipment
  • operating alternating current (AC) systems and conducting operator preventive maintenance according to manufacturer recommendations, regulations and vessel operating procedures to ensure safe operation
  • operating electrical systems and equipment according to manufacturer recommendations, regulations and vessel operating procedures to ensure safe operation providing high quality reports
  • performing maintenance tasks, including: battery maintenance; testing: alarm systems, emergency alternator, power and lighting systems
  • recognising electrical system faults and, where necessary, taking steps to make them immediately safe and initiate repair
  • selecting and using appropriate processes, tools and equipment

Knowledge evidence

  • AC systems not exceeding 440 volts (V) AC
  • batteries, including types, care and maintenance, and hazards
  • care of electrical systems and equipment in general including fault recognition
  • charging systems, including: alarms/indicators, regulators, connecting batteries
  • electric systems, including above 240 V AC and up to 440 V AC
  • fault identification, location and safety implications
  • operation and maintenance of starter motors, alternators and associated equipment
  • personal safety
  • protective devices on switchboards
  • shore power connection
  • special requirements for electrical system breakdown/s, including: isolation procedures, stopping alternator/s, stopping main engine/s, switching to emergency power
  • use of fuses and circuit breakers, including selection of correct capacity

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing MARB047

What does an assessment tool for MARB047 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for MARB047 needs to address all 70 unit components: 7 elements with 46 performance criteria, 12 performance evidence requirements, 12 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for MARB047?

Auditori pulls the current release of MARB047 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for MARB047 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing MARB047 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of MARB047, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your MARB047 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate MARB047 free