ICTCBL320Jumper metallic conductor cable in the access network

Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.

Every new account includes a free credit — no card, no subscription.

What an assessment for ICTCBL320 must cover

40 assessable components: 4 elements (21 performance criteria), 5 performance evidence and 7 knowledge evidence requirements, plus 7 foundation skills. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.

Elements & performance criteria

1 Prepare cabinet and termination frame for jumpering

  • 1.1Arrange access according to customer and individual worksite requirements
  • 1.2Set up work site to ensure public safety and to comply with utility provider, local, state and commonwealth requirements
  • 1.3Inspect site to develop work health and safety (WHS) plan and notify appropriate personnel of identified safety hazards
  • 1.4Prepare for cable jumpering work observing client practices, cable type, termination systems, earthing and protection and relevant legislative requirements
  • 1.5Select correct jumpering activities for installation according to client practices
  • 1.6Identify remote power feeding services that operate at above telecommunications network voltage (TNV) and special services that terminate in the cabinet of housing
  • 1.7Take necessary precautions to work safely with network voltages and minimise service disruption to special services
  • 1.8Remove all contaminants from worksite that may adversely affect jumpering and prepare worksite to ensure adequate visibility to minimise errors and reduce eye strain
  • 1.9Plan block locations following client practices within the frame and allow for capacity to expand jumpering where possible

2 Jumper terminal blocks on frame

  • 2.1Install terminating modules to frame according to manufacturer’s specifications
  • 2.2Set up jumpering reel near source terminal block and draw jumper through frame
  • 2.3Terminate jumper to block and return, cut and terminate source end of jumper
  • 2.4Identify and label jumpers according to client practices
  • 2.5Install over-voltage protection devices to all cables with metallic component where required
  • 2.6Earth cable shield to manufacturer’s specifications and industry standards

3 Test jumpering and seal closure

  • 3.1Conduct visual inspection to confirm that jumper is not kinked or jammed
  • 3.2Test termination to satisfy performance specifications and record results if required
  • 3.3Close housing, seal and re-pressurise where necessary

4 Complete records and restore site

  • 4.1Update records and plans accurately with cabling details according to industry codes of practice and current Australian standards
  • 4.2Remove installation waste and debris from worksite and dispose of according to environmental requirements to maintain safe worksite conditions
  • 4.3Notify appropriate personnel about completion of job and obtain sign off

Performance evidence

  • Evidence of the ability to:
  • plan and prepare for jumpering activity including: - arranging safe access to site - identifying special services and remote power feeds - following appropriate procedures
  • carry out jumpering activity including: - populate terminal frames with new terminal blocks where necessary - running jumpers through frame and terminate jumper to terminal blocks - using correct methods to terminate a range of jumpers - conducting tests and interpreting cable test results for several different types of lead-in faults - interpreting and applying relevant legislative requirements
  • finalise jumpering activity including: - updating records and plans to show cable locations - restoring site to required condition - obtaining final sign off.
  • Note: If a specific volume or frequency is not stated, then evidence must be provided at least once.

Knowledge evidence

  • list the termination tools required for the work activity and explain how to operate them according to safety and manufacturer’s guidelines
  • describe the features and operating requirements of testing equipment
  • describe the process used to install and maintain cabling products according to manufacturer’s guidelines
  • outline legislation, codes of practice and other formal agreements that impact on the work activity
  • describe specific work health and safety requirements relating to the activity and site conditions
  • explain termination methods and performance requirements for jumpering activity
  • describe typical issues and challenges that occur on site and how to address them.

Foundation skills

  • Reading: Interprets textual information from relevant sources to identify relevant and key information
  • Writing: Uses clear, specific and industry related terminology to complete workplace documentation
  • Oral communication: Interacts effectively in verbal exchanges using appropriate language, listening and questioning skills to convey and clarify information
  • Numeracy: Takes readings and measurements and interprets results
  • Navigate the world of work: Complies with policies, procedures and legislative requirements relevant to own role
  • Interact with others: Identifies and follows accepted communication practices and protocols when liaising with clients, colleagues and others
  • Get the work done: Plans, sequences and carries out tasks to meet required outcomes - Analyses task requirements to decide on appropriate equipment and practices

Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.

See what you get before you start

Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:

Questions about assessing ICTCBL320

What does an assessment tool for ICTCBL320 need to cover?

To satisfy the Principles of Assessment and Rules of Evidence, an assessment for ICTCBL320 needs to address all 40 unit components: 4 elements with 21 performance criteria, 5 performance evidence requirements, 7 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.

How does Auditori generate an assessment tool for ICTCBL320?

Auditori pulls the current release of ICTCBL320 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.

Is the first assessment tool really free?

Yes. Every new account includes one free credit — enough to generate the complete assessment tool for ICTCBL320 — with no card and no subscription required. After that it's pay-as-you-go per unit.

Can I check my existing ICTCBL320 assessment instead of generating a new one?

Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of ICTCBL320, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.

Related units

Your ICTCBL320 assessment tool, in minutes.

First unit free. No card, no RTO registration, no subscription.

Generate ICTCBL320 free