CPPFES2035 — Identify, inspect and test fire and smoke doors
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for CPPFES2035 must cover
36 assessable components: 4 elements (15 performance criteria), 3 performance evidence and 18 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Plan and prepare for service operation.
- 1.1Read work instructions to clarify service timeframes, client needs, and site and fire and smoke door locations.
- 1.2Discuss planned service procedures with relevant persons to clarify client needs and expectations.
- 1.3Plan work activities to comply with relevant Australian Standards, NCC, regulatory, work health and safety (WHS) and workplace requirements.
- 1.4Identify potential and actual breaches of rules and regulations associated with work instructions and take required action to ensure compliance according to regulatory and workplace requirements.
- 1.5Select and use required personal protective equipment (PPE).
- 1.6Arrange access to worksite and communicate with responsible entity and affected persons to advise duration and impact of planned service procedures and to ensure alternative safety arrangements are implemented.
- 1.7Identify and to control hazards in the work area according to workplace requirements.
2 Identify fire or smoke doors and their components.
- 2.1Identify fire or smoke door according to purpose, operation and location.
- 2.2Identify and locate fire or smoke door components, hardware items and seals according to design, operation and purpose.
3 Inspect and test fire or smoke doors.
- 3.1Inspect fire or smoke door and associated frame, components, hardware items and seals to identify defects, damage or signs of wear according to the relevant maintenance schedule.
- 3.2Check fire or smoke door marking and labelling against requirements of the relevant Australian Standard.
- 3.3Operate fire or smoke door to test and verify correct working order according to the relevant Australian Standard, manufacturer and workplace requirements.
- 3.4Record identified defects and non-compliances according to regulatory and workplace requirements.
4 Finalise service operation.
- 4.1Complete service documentation and report outstanding defects, non-compliances and recommended rectifications according to Australian Standards, regulatory and workplace requirements.
- 4.2Leave client premises in a clean and tidy condition.
Performance evidence
- identifying, inspecting and testing 20 fire or smoke doors that are installed across two different sites
- at least one fire door and one smoke door
- three different types of fire or smoke doors
Knowledge evidence
- action to take when a breach of regulation, work health and safety (WHS) or other policy occurs when identifying, inspecting and testing fire and smoke doors
- correct installation procedures and dangers of incorrect installation of fire and smoke doors
- fire and smoke doors and fire shutter variables, including types, components, hardware, seals and wall types
- implications of not complying with regulatory requirements when inspecting and testing fire and smoke doors
- key features of legislation, regulations, codes and Australian Standards relevant to identifying, inspecting and testing fire and smoke doors and fire shutters:
- fire and smoke containment
- maintenance schedules
- National Construction Code (NCC) and deemed-to-satisfy requirements
- records and documentation
- key physical features, definition of, and purpose of fire and smoke doors and fire shutters
- operational requirements for inspecting and testing fire and smoke doors and fire shutters
- principles of passive fire protection related to overall fire safety systems
- procedures for determining fire resistance levels
- range of fire and smoke door tags
- technical terms relating to fire and smoke door and fire shutter inspection and testing
- workplace requirements for identifying, inspecting and testing fire and smoke doors:
- maintenance of tools and equipment
- WHS, including hazard and risk identification and control
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing CPPFES2035
What does an assessment tool for CPPFES2035 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for CPPFES2035 needs to address all 36 unit components: 4 elements with 15 performance criteria, 3 performance evidence requirements, 18 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for CPPFES2035?
Auditori pulls the current release of CPPFES2035 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for CPPFES2035 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing CPPFES2035 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of CPPFES2035, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- CPPFES2003 — Safely move loads and dangerous goods
- CPPFES2004 — Identify and report on types of installed fire safety equipment and systems
- CPPFES2005 — Demonstrate first attack firefighting equipment
- CPPFES2006 — Prepare for installation and servicing operations
- CPPFES2007 — Maintain quality of work and promote continuous improvement
- CPPFES2010 — Inspect and test fire hose reels
- CPPFES2011 — Install portable fire extinguishers, fire cabinets and fire blankets
- CPPFES2016 — Inspect, test and maintain delivery layflat fire hoses
- CPPFES2020 — Conduct routine inspection and testing of fire extinguishers and fire blankets
- CPPFES2021 — Inspect, test and maintain fire extinguishers
- CPPFES2025 — Inspect, test and maintain gaseous fire-suppression systems
- CPPFES2026 — Inspect and test emergency and exit lighting systems
Your CPPFES2035 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate CPPFES2035 free