CPCPFS3043 — Conduct functional water flow testing
Generate a complete, audit-ready assessment tool for this unit in minutes: candidate assessment, assessor guide with model answers, and a coverage matrix mapped to every component below. Reviewed and approved by your qualified person, exported under your branding.
Every new account includes a free credit — no card, no subscription.
What an assessment for CPCPFS3043 must cover
142 assessable components: 4 elements (26 performance criteria), 4 performance evidence and 112 knowledge evidence requirements. An audit-defensible tool maps every question and task back to these — that mapping is the coverage matrix Auditori generates alongside the assessment.
Elements & performance criteria
1 Plan the work
- 1.1Identify, confirm and apply water flow testing requirements from relevant job plans and specifications, codes, Australian Standards, manufacturer’s specifications and jurisdictional requirements.
- 1.2Identify and apply workplace policies and procedures, work health and safety (WHS) and environmental requirements.
- 1.3Check location and equipment against legislative and industry requirements and take action according to organisational requirements to ensure compliance.
- 1.4Select and check serviceability of tools, equipment and personal protective equipment (PPE).
- 1.5Identify and isolate relevant plant and system interfaces.
- 1.6Confirm that wastewater from flow test will not cause any damage or issues to site or surrounding area.
- 1.7Identify appropriate test points and required water flow test equipment.
- 1.8Locate and identify types of water supply isolating valves.
2 Prepare for work
- 2.1Apply appropriate workplace procedures and risk control measures.
- 2.2Depressurise flow test point pipework.
- 2.3Attach water flow test equipment according to manufacturer instructions and organisational requirements.
- 2.4Install gauges of known accuracy.
- 2.5Determine system water pressure and flow requirements from block plan.
- 2.6Select and chart at least four points to take readings when flow testing according to manufacturer’s charts for the flow test equipment.
- 2.7Operate valves to isolate water supplies.
- 2.8Document all information from site block plan.
3 Conduct functional water flow proving and load test, and record results
- 3.1Perform tests on each water supply to verify that systems function as intended, stopping at a minimum of four points and recording installation, town’s main and/or pump suction and discharge pressures.
- 3.2Record pump driver RPM at the drive shaft, temperature of driver and oil pressure.
- 3.3Monitor cooling system closely while conducting flow test.
- 3.4Record temperature of pump room when conducting test.
- 3.5Compare test results with legislative and industry requirements.
- 3.6Identify all defects and nonconformances and report according to AS 1851 Routine service of fire protection systems and equipment.
- 3.7Document and graph results and forward report to relevant persons for action.
- 3.8Reinstate system according to organisational requirements.
4 Clean up
- 4.1Clear the work area, and dispose of, reuse or recycle materials in accordance with state and territory legislation and workplace policies and procedures.
- 4.2Clean tools and equipment, check for serviceability and report any damage, and store and secure according to workplace procedures.
Performance evidence
- conducting a load test on a wet and general electrical pumpset according to AS 1851 Routine service of fire protection systems and equipment
- conducting a load test on a wet and general diesel pumpset according to AS 1851 Routine service of fire protection systems and equipment
- conducting a functional water-flow test on a hydrant system incorporating a pumpset
- conducting two functional water-flow tests on a hydrant system: one with a portable flow meter, one connected by a length of fire hose
Knowledge evidence
- basic principles of hydraulics
- basic principles of operation and purpose of components of a water-based fire protection system:
- deluge control valve assembly components
- alarm wet control valve assembly components
- booster valve assembly
- circulation and system pressure relief valves
- compression ignition engine governing controls
- differential pressure gauges
- hand tachometers
- hydrant landing valve assembly
- isolation and control valves
- manometers
- orifice plates
- pitot tube water flow test instrument
- pressure and flow switches
- pressure gauges
- pump controllers and ancillary equipment for control and indication
- pumpsets
- solenoid valves
- system block plans
- system pressure gauge schedules
- throttling valves
- ultrasonic flow measuring equipment
- ultrasonic thickness gauges
- venturi devices
- water supply tanks (atmospheric, pressure and suction with priming tanks)
- general operation of a pumpset:
- compression ignition engine governing control devices
- cooling systems
- design speed requirements
- exhaust systems
- fuel systems
- full load operation
- normal running operation
- pre-start and post-start checks
- pumpset performance curve
- pumpset controllers
- starting and stopping methods
- suction and discharge connections and pressures readings
- general operation of water-based fire-suppression systems
- terminology used in relation to water-based fire-suppression systems
- water-based fire-suppression system components:
- air compressors fitted to control valves
- circulation and system pressure relief valves
- electric motor specification plate
- flow switches and associated testing equipment
- isolating valves associated with water-based fire-suppression system
- mains water supply underground key-operated valve location
- most hydraulically disadvantaged testing point on a system hose reel and hydrant system
- pressure gauges
- pumpsets associated with water-based fire-suppression systems
- pump starting switches
- suction inlet strainers or screen on a static water supply for water-based fire-suppression system
- system block plans
- system main alarm bell or alarm strobe indicating building entry point for emergency personnel
- system pressure gauge schedules
- water supply tanks, water level indicators and automatic inflow valves
- water-based fire-suppression system control and alarm valves and ancillary equipment for control and alarm operation indication or interface
- controls on the pumpset controller panel:
- fuel gauges
- indicators
- main isolating switch
- water-based fire-suppression system applications as defined in AS 2118 Automatic fire sprinkler systems
- legislative and industry requirements:
- relevant Commonwealth and state or territory building acts, regulations and codes, such as the National Construction Code (NCC)
- AS 1851 Routine service of fire protection systems and equipment
- relevant legislation relating to testing of fire protection equipment
- organisational requirements:
- client-specific contractual requirements
- documentation and information systems and processes
- legal and organisational policies and guidelines, including personnel practices and guidelines outlining work roles, responsibilities and delegations
- using electronic job scheduling and communication devices
- commissioning tests detailed in relevant Australian standards and manufacturers documentation to verify performance of an installed, repaired or altered piece of equipment or system
- checking for compliance including applying inspections, tests and survey requirements to equipment and systems according to relevant Australian standards to determine that they are:
- capable of operating as intended when originally installed
- still suitable for the fire hazard or risk being protected as no change in occupancy or use of the area protected has occurred since the equipment or system was installed or last modified
- providing the coverage and protection needed to meet original design and performance requirements
- checking for compliance, including reviewing documentation to verify that installed systems comply with legislative and industry requirements such as:
- buildings essential services or fire safety measures listing
- relevant Commonwealth and state or territory building acts, regulations and codes
- relevant Australian standards listed on essential service listing
- environmental regulations
- water-based fire-suppression systems as defined in AS 2118 Automatic fire sprinkler systems and AS 2419 Fire hydrant installations:
- combined sprinkler and hydrant systems
- deluge systems
- dry systems
- hydrant systems
- pre-action or recycle systems
- residential and domestic systems
- tail-end systems
- specific locations where test equipment can be attached to measure and record water flow and pressure to meet legislative and industry requirements
- water flow test equipment:
- differential pressure gauges
- hand tachometers
- manometers
- orifice plates
- pitot tube water flow test instrument
- ultrasonic flow measuring equipment
- ultrasonic thickness gauges
- venturi devices
- system interface components such as flow, pressure, tamper and valve positioning switches that operate signals between the water-based fire-suppression system and other services such as:
- building heating, ventilation and air conditioning (HVAC) services
- fire brigade monitoring providers
- other life safety systems:
- warning systems
- fire indicator panel (FIP)
- methods of applying sustainability principles and concepts
- routine service frequency schedules:
- reference to AS 1851 Routine service of fire protection systems and equipment schedules of work conducted at regular frequencies that relate to the work scope for weekly, monthly, and six-monthly inspection and testing activities
- how to access relevant information, including codes and standards
- tools, materials and equipment used for conducting functional water flow testing
- work health and safety (WHS) requirements for conducting functional water flow testing
Unit content sourced from training.gov.au — © Commonwealth of Australia, licensed under CC BY 4.0. Auditori is not affiliated with the Department of Employment and Workplace Relations.
See what you get before you start
Real, unedited Auditori output (RIIHAN201E shown), branded for a sample RTO:
Questions about assessing CPCPFS3043
What does an assessment tool for CPCPFS3043 need to cover?
To satisfy the Principles of Assessment and Rules of Evidence, an assessment for CPCPFS3043 needs to address all 142 unit components: 4 elements with 26 performance criteria, 4 performance evidence requirements, 112 knowledge evidence requirements, and the foundation skills. A coverage matrix mapping each question and task to these components is what an auditor looks for.
How does Auditori generate an assessment tool for CPCPFS3043?
Auditori pulls the current release of CPCPFS3043 from training.gov.au and generates a complete package: candidate assessment, assessor guide with model answers and observation criteria, and a coverage matrix mapping every component. A suitably qualified person then reviews and approves the draft in a built-in workflow — consistent with ASQA's guidance on AI use in VET — before export as branded PDF and editable Word.
Is the first assessment tool really free?
Yes. Every new account includes one free credit — enough to generate the complete assessment tool for CPCPFS3043 — with no card and no subscription required. After that it's pay-as-you-go per unit.
Can I check my existing CPCPFS3043 assessment instead of generating a new one?
Yes — upload your existing assessment or learner guide and Auditori maps it against every element, performance criterion, PE and KE of CPCPFS3043, showing exactly what's covered and what's missing. Mapping costs a quarter of a credit.
Related units
- CPCPFS2021 — Connect static storage tanks for fixed fire protection systems
- CPCPFS2022 — Install portable fire equipment
- CPCPFS3030 — Design fire sprinkler systems using pre-calculated charts and tables
- CPCPFS3031 — Fabricate and install fire hydrant and hose reel systems
- CPCPFS3034 — Install control valve assemblies, actuating devices and local alarms
- CPCPFS3036 — Install special hazard systems
- CPCPFS3037 — Install residential life safety sprinkler systems
- CPCPFS3038 — Test and maintain fire hydrant and hose reel installations
- CPCPFS3040 — Conduct basic functional testing of water-based fire-suppression systems
- CPCPFS3041 — Inspect and test fire pumpsets
- CPCPFS3042 — Conduct annual routine service of complex water-based fire-suppression systems
- CPCPFS3044 — Install distribution and range pipes
Your CPCPFS3043 assessment tool, in minutes.
First unit free. No card, no RTO registration, no subscription.
Generate CPCPFS3043 free